STAIR CLIMBER SOLIDSTATE CONTROLLER
The Stair Climber Solid State Controller is a fully solid state Pulse Width Modulated (PWM) controller.
Its advanced microprocessor based control implements a state-of the-art power MOSFET motor drive.
Advanced features provide improved functionality, smoother operation, reduced mechanical stress,
and protects against abuse and system faults.
ADVANTAGES
 
 
 Reduced peak current reduces power loss in batteries, motor, and cabling.
 
 Reduced peak current reduces battery stress, increased service life.
 
 Reduced peak torque reduces mechanical stress, increasing service life of
 
 
 Smooth operation "feel" by controlled acceleration and deceleration (motor voltage ramp-up and ramp-
down) eliminating jerkiness.
 Automatically slows speed with heavy loads, improving control and safety.
 Overload protection shuts off if lift load is too heavy.
 Protects batteries by limiting minimum loaded voltage to 8.5 volts.
 Internal protections for many types of internal and external faults.
 Protects controller by inhibiting operation if battery voltage is to high.
 Detects battery+ or battery- short to frame and inhibits motor operation.
 Limits continuous operation to <30 seconds. Control wiring fault protection.
 Alerts to low or excess control heating (from over-use).
 Alerts to overload or excess continuous run time (control fault).
 Alerts to battery+ or battery- short to frame.
 Alerts to internal controller faults.
 Low standby power of less than 20mA.
 
SPECIFICATIONS
Operating Voltage Range:
Maximum Voltage:
Over-voltage shut-off
Motor Current Limit:
Output Time Rating (@100 Amps):
Continuous Current (Ambient<25ºC)
Maximum Run without stop:
Input control current, Max.(@ 13V)
Standby Current (@12.6V)
Buzzer or LED output:
Standby Time (25% charge remains)
Operating Temperature Range:
Storage Temperature Range:
Environmental:
 
FAULT ALERTS
Faults are indicated by a buzzer producing a series of beeps to indictate various faults as follows:
One Beep
- Overload condition (too much weight on Unit) - Reduce Load
- Maximum run time (25-30sec.) exceeded - Release and re-apply switch
Two Beeps - Low Battery - Recharge Battery
Three Beeps - Battery+ or Battery- shorted to frame. HALT USE AND RETURN FOR REPAIR
System Fault - FAULTY UNIT -HALT USE AND RETURN FOR REPAIR
Four Beeps - Overheating due to excessive use (many minutes) - Allow five minutes to cool
 
8.5V - 14.4V
16.0V (non-operating)
15.5V
100 Amps (+10%, -5%)
1.5Min. Minimum (ambient & initial temp<25ºC)
65 Amps (75 Amps in LE-Series Unit)
25 to 30 Seconds (sofware limited)
0.3 mA
< 18mA
5 Volts, maximum 15mA
40 days (start with 20 AH battery, fully charged)
-25ºC to 50ºC
-40ºC to 85ºC
Solid State Controller Unit is100% RoHS compliant.
6.02
®
PowerMate
Operation Manual
 
PN 013710 Rev.D2
Component 052810
Eng. 12/ 12/ 12

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Powermate Aluminum LE Series

This manual is also suitable for:

Aluminum le-2Aluminum le-1

Table of Contents