18 May, 1999
7.3 ERROR CODES
These error codes are listed in the system parameter list.
Fatal errors
When a fatal error occurs, an error code is displayed in the LCD. (For example,
"Error 59".) The machine cannot clear fatal errors by turning the power off and on.
A fatal error can be canceled using the RAM display/rewrite mode (Service
function 82).
NOTE: Perform the following operation to cancel a fatal error.
1) Enter the RAM display/rewrite mode. (See 4.1: Service functions)
2) Select the hexadecimal display mode.
3) Set the address to "11111111".
4) Press the Start key.
5) Move the cursor to the data area.
6) Change the value to "00".
7) Press the Stop key.
Semi fatal errors
When a semi-fatal error occurs, an error code is displayed in the LCD. (For
example: "Error 90".) The machine will clear this error when the power is turned off
and on.
Error
Error Type
Semi-
Code Error
fatal
Error
9
01
9
04
Fatal
Error
Too many errors
Line disconnection
7-25
Description
The other end sent an RTN after
receiving a page, because there
were too many errors
1. Line disconnected just after
sending TCF
2. Line disconnected when sending
the image data
3. No post-message command
from the other end when receiving
non-ECM data
4. No post-message response from
the other end after a page was
sent
5. EOR-NULL was sent
6. ERR was sent in response to the
received EOR-NULL
7. ERR was sent in response to the
received EOR-MSP
ERROR CODES