Newco FKP-4T Manual page 13

Single serving automatic pod machine
Table of Contents

Advertisement

THESE MACHINES ARE EQUIPPED WITH A FLOWMETER-
Fresh Cup pod brewer a few times. If the volume dispensed is comparable to the amount
expected from your Button Settings (which are set in the programming menu as
described BELOW) and consistent and the pulsing is acting as expected you are done.
However if your dispensed volume is larger or smaller than expected the easiest way to
adjust it is to adjust the "OZ PER TICK" using the FLOWMETER ADJUST feature in the
programming menu.
NOTE: THE MACHINE HAS BEEN CALIBRATED AT THE FACTORY AND HAS BEEN ADJUSTED
TO BREW INTO AN 8 OUNCE CUP WITH APPROX 7 OUNCES OF COFFEE FOR BREW
STRENGTHS OF MILD, MEDIUM AND BOLD. NO FURTHER ADJUSTMENTS ARE NECESSARY
IF THE FACTORY DEFAULTS ARE USED.
Set Pod Count
the number of pods the brewer will hold before
signaling that the bin is full. The range is 10 to 100
pods, with the default at 30. Setting the pod count
under 10 turns off the counter so the empty waste bin
message will not display. As with most of the entries,
pressing the green (+) and (-) buttons will change the
entry then press the Blue "Return" button to exit.
Flowmeter Adjustment
displays the value used to represent the amount of
liquid for one tick of the flow meter count. Each tick
adjusts the value approximately 2/10
While in this entry, pressing the green (-) key will
decrement and the green (+) key will increment this
value. This can be used to fine-tune the amount of
liquid that is dispensed.
13
: In this entry the user may set
Please run your
:
This entry
th
of an ounce.

Hide quick links:

Advertisement

Table of Contents
loading