Newco CB Dual Service Manual

Newco CB Dual Service Manual

Commercial barista series
Hide thumbs Also See for CB Dual:

Advertisement

Quick Links

SERVICE MANUAL
COMMERCIAL BARISTA SERIES
Models: CB, CB-2, CB-5, CB-7 & CB Dual

Advertisement

Table of Contents
loading

Summary of Contents for Newco CB Dual

  • Page 1 SERVICE MANUAL COMMERCIAL BARISTA SERIES Models: CB, CB-2, CB-5, CB-7 & CB Dual...
  • Page 2 20-Aug-12...
  • Page 3 Introduction The Commercial Barista series by Café 98 incorporates the latest features in brewer control technology along with the proven Brewing system you have come to rely on. Although providing for enhanced functionally brewer control remain intuitive and setup of key operating parameters couldn’t be easier. Multiple brew volumes, visa-brew delay, tank temperature set point, brew mode, filter parameters and more are all set from the front control panel using a digital display for precise control.
  • Page 4 Introduction (Continued) Number of Brews – The number of brew cycles started may be tracked with this feature. The accumulated number of cycles may be reset. Using the brew buttons, first display “Cir” when in the program mode, and then depress cancel. Power Mode –...
  • Page 5 Introduction (Continued) Sequence Of Programming Steps For Dual Barista Controller • Simultaneously depress and hold the left & middle brew buttons until display lights up (approx. 10 seconds). • You are now in the Program Mode. Functions to be programmed appear in the order in which they are shown in the following table.
  • Page 6: Error Messages

    Introduction (Continued) Error Messages The following table explains the error messages, which may be encountered, on the brewer. Going into the program mode, using the brew button to display “Cir” and then pressing the cancel button will clear the error messages.
  • Page 7 Wiring Diagram [Single] 20-Aug-12...
  • Page 8 Wiring Diagram [Dual] 20-Aug-12...
  • Page 9 When this PDS valve is installed on equipment with pressurized hot water coil faucets, check to see if a back flow preventer is incorporated in the water line. If not, it may be necessary to install a pressure relief valve. If you have any questions please call NEWCO technical support at 1.800.556.3926. Timer Setting Required To Obtain Desired Water Volume...
  • Page 10: Installation Instructions

    Installation Instructions Note: Cost of installation and any subsequent fine-tuning is the responsibility of the buyer. Warning: Read follow installation instructions before plugging in machine to an electrical outlet. 1. Remove the machine from shipping carton. It is strongly recommended to perform a visual inspection of the machine inside out checking for loose connections on either control board or for damage to outlet valve that might have been caused by mishandling during shipment.
  • Page 11 Recommended Terminal Block lug torque specifications P/N 701972 – 35 In. Ibs. P/N 701000 – 35 In. Ibs P/N 511053 – 20 In. Ibs 20-Aug-12...
  • Page 12: Newco Product Warranty

    REPLACEMENT OR REFUND. In no event shall NEWCO be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claim’s of BUYER’S customers, cost of capital, cost of downtime, cost of substitute equipment, facilities or services, or any other special, incidental, or consequential damages.
  • Page 13 20-Aug-12...
  • Page 14 20-Aug-12...

This manual is also suitable for:

Cb-2Cb-5Cb-7

Table of Contents