6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit
RAS-B10GKVP-E, RAS-B13GKVP-E, RAS-B16GKVP-E
No.
Parts name
1
Fan motor (for indoor)
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
4
Louver motor
6-2. Outdoor Unit
RAS-10GAVP-E, RAS-13GAVP-E, RAS-16GAVP-E
No.
Parts name
1
Reactor
2
Outside fan motor
3
Suction temp. sensor (TS sensor)
4
Discharge temp. sensor (TD sensor)
5
Outside air temp. sensor (TO sensor)
6
Heat exchanger temp. sensor (TE sensor)
7
Terminal block (6P)
8
Compressor
9
Coil for P.M.V.
10
Coil for 4-way valve
Type
MF-280-30-5R
( – )
( – )
MP24Z
Model name
CH-57
ICF-140-43-4R
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
——
DA111A1F-20F1
CAM-MD12TF
VHV
– 18 –
Specifications
DC280–340V, 30W
10k
at 25°C
10k
at 25°C
Output (Rated) 1W, 16 poles, DC12V
Rating
L = 10mH, 16A × 2
DC140V, 43W
10k
(25°C)
62k
(20°C)
10k
(25°C)
10k
(25°C)
20A, AC250V
3-phases 4-poles 750W
DC12V
AC220–240V

Hide quick links: