Wolf FGB-K Series Installation And Maintenance Instructions For Contractors page 29

Wall mounted gas condensing/combi boiler
Hide thumbs Also See for FGB-K Series:
Table of Contents

Advertisement

Display
Display menu (info button)
1
2
Info button (3)
3064458_201811
15. Control unit
DHW mode
(A flashing symbol indicates an active heat demand for DHW heating.)
Only shown if DHW heating is available.
Heating mode
(A flashing symbol indicates an active heat demand for heating operation.)
Changes are only possible when the heating curve is disabled.
Shown when there are active fault codes.
Reset button (press 1x briefly).
Fault codes are reset.
Display of temperature, fault codes, HG parameters and set values.
In emissions test mode, the modulation level is displayed.
Burner modulating levels.
1% - 30%, 30% - 75%, 75 - 100%
Service
- Emissions test mode enabled.
- Fault is displayed.
Indication of water pressure in the heating system.
Venting program
When switching on the mains power, following a power failure, if the water pressure is below
0.5 bar or if the high limit safety cut-out is reset, the venting program runs for 2 minutes.
The gas fan runs for the first 30 s and then stops. The pump and 3-way diverter valve are
activated alternately. To cancel, press "reset".
To bring up the display level, briefly press info button (3).
Use buttons 1 and 2 to scroll to the corresponding display value, e.g. I06.
Press button 6 or 7 to display the associated value.
Press button 1 or 2 to return to the display selection.
To exit the display menu, press the info button or wait for 2 min.
7
Name
i00
1)
6
i01
i02
i03
i04
i05
i06
i07
i08
i09
i10
i11
i12
i13
from FW 1.10
1)
Description
Flow sensor temperature
Flow temperature
Return sensor temperature
DHW sensor temperature
DHW solar inlet / DHW cylinder temperature
Flue gas sensor temperature
Outside temperature
Fan speed
PWM pump speed
DHW flow rate
Actual water pressure
High limit safety cut-out
Flame current
Firmware version
Display in
(°C)
(°C)
(°C)
(°C)
(°C)
(°C)
(rpm x 60)
(%)
(l / min)
bar
ON and OFF
(µA x 10)
Version x.xx
29