Terminal strip
Power supply 230 V / 50 Hz
Room thermostat input (jumper)
Please note:
No external voltage must be
connected to input E1, as this
would destroy the PCB.
Outside temperature sensor
T_Outside
(5K NTC)
Cylinder temperature sensor
T_DHW (5K NTC)
eBus
24
14. Electrical connection
3064458_201811