Lincoln Electric EAGLE 10,000 Service Manual page 45

Hide thumbs Also See for EAGLE 10,000:
Table of Contents

Advertisement

F-9
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
Engine will not go to high idle when
attempting to weld. Welding output
is normal when Idler Switch is in
"HIGH" position.
Automatic idle
function works properly when the
auxiliary power is loaded.
Engine will not go to high idle when
attempting to weld or when the aux-
iliary power is loaded. Welding out-
put and auxiliary power output is
normal when Idler Switch is in the
"HIGH" position.
Engine will not go to high idle when
the Auxiliary Power is loaded. The
Idle Circuit works OK with a weld-
ing load.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
All manuals and user guides at all-guides.com
TROUBLESHOOTING AND REPAIR
POSSIBLE AREAS OF
MISADJUSTMENT(S)
ENGINE PROBLEMS
1. Make sure the welding cables
and connections are tight.
1. Make sure the welding cables
and connections are tight.
2. Automatic idler may not function
if the auxiliary power is loaded to
less than 150 Watts.
1. Automatic idler may not function if
the auxiliary power is loaded to
less than 150 Watts.
CAUTION
EAGLE™ 10,000
RECOMMENDED
COURSE OF ACTION
1. Check for broken or faulty con-
nections in the sensing lead
(#254). Make sure the connec-
tions are tight at the Electrode
Switch See Wiring Diagram.
Output Terminal and the Range
2. Make sure the lead is routed
through the toroid.
1. Check for broken or faulty con-
nections in the Toroid leads.
(#260 and #261). Make sure
their connections are tight at the
Diagram.
PC Board.
See
2. The Toroid may be faulty.
3. The Printed Circuit Board may
be faulty. Replace.
1. If the machine works OK when
set to High Idle,mMake sure that
leads #3 and #6 are wrapped
correctly through the Toroid.
2. If the machine does not function
properly at High Idle check that
the connections are good at the
circuit breakers and that the cir-
cuit breakers are functional.
F-9
Wiring

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents