Lincoln Electric Red-D-Arc EX350i Operator's Manual

Spec-built welding equipment
Hide thumbs Also See for Red-D-Arc EX350i:

Advertisement

Quick Links

IM764
RED-D-ARC
March, 2002
EX350i
10945
For use with machines having Code Numbers:
OPERATOR'S MANUAL
Red-D-Arc Spec-Built Welding Equipment
This RED-D-ARC welder is built to RED-D-ARC Extreme Duty
design specifications by Lincoln Electric.
Safety Depends on You
This welder is designed and built with safety in mind.
However, your overall safety can be increased by proper installation
... and thoughtful operation on your part.
DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT
WITHOUT READING THIS MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED THROUGHOUT.
And, most importantly, think before you act and be careful.
1-800-245-3660
North America's Largest Fleet of Welding Equipment

Advertisement

Table of Contents
loading

Summary of Contents for Lincoln Electric Red-D-Arc EX350i

  • Page 1 OPERATOR’S MANUAL Red-D-Arc Spec-Built Welding Equipment This RED-D-ARC welder is built to RED-D-ARC Extreme Duty design specifications by Lincoln Electric. Safety Depends on You This welder is designed and built with safety in mind. However, your overall safety can be increased by proper installation ...
  • Page 2: California Proposition 65 Warnings

    351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199. BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
  • Page 3: Electric Shock Can Kill

    SAFETY ARC RAYS can burn. ELECTRIC SHOCK can 4.a. Use a shield with the proper filter and cover kill. plates to protect your eyes from sparks and 3.a. The electrode and work (or ground) circuits the rays of the arc when welding or observing are electrically “hot”...
  • Page 4 SAFETY WELDING SPARKS can CYLINDER may explode cause fire or explosion. if damaged. 6.a. Remove fire hazards from the welding area. 7.a. Use only compressed gas cylinders If this is not possible, cover them to prevent containing the correct shielding gas for the the welding sparks from starting a fire.
  • Page 5 SAFETY zones où l’on pique le laitier. PRÉCAUTIONS DE SÛRETÉ 6. Eloigner les matériaux inflammables ou les recouvrir afin de Pour votre propre protection lire et observer toutes les instructions prévenir tout risque d’incendie dû aux étincelles. et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté...
  • Page 6 QUALITY product by Lincoln Electric. We want you Thank You to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Please Examine Carton and Equipment For Damage Immediately When this equipment is shipped, title passes to the purchaser upon receipt by the carrier.
  • Page 7: Table Of Contents

    TABLE OF CONTENTS Page Installation .......................Section A Technical Specifications ..................A-1 Safety Precautions ..................A-2 Select Suitable Location..................A-2 Stacking ......................A-2 Tilting.......................A-2 Input and Grounding Connections ..............A-2 Power Cord Connection ..................A-2 Connection of Wire Feeders to EX350i ............A-2 Remote Control of Invertec ................A-3 Undercarriage Mountings................A-3 Parallel Operations..................A-4 ________________________________________________________________________...
  • Page 8: Installation

    INSTALLATION TECHNICAL SPECIFICATIONS - RED-D-ARC EX350i INPUT AC VOLTAGE & DC OUTPUT Product Ordering Input AC Rated DC Output Output Weight Dimensions Open Name Information Voltage Amps/Volt Range with Cord HxWxD Circuit /Duty Cycle (continuous) Voltage 208-230/ 14.8” x 13.3” x...
  • Page 9: Safety Precautions

    INSTALLATION • Open the access panel on the rear of the machine. SAFETY PRECAUTIONS • For 200 or 230: Position the large switch to 200- WARNING 230. For higher voltages: Position the large switch to ELECTRIC SHOCK can kill. 380-575. •...
  • Page 10: Remote Control Of Invertec

    INSTALLATION Cobramatic Connection Instructions LN-7 Connection Instructions • Turn the EX350i power switch "off" • Turn the EX350i power switch “off”. • Connect the control cable from the Cobramatic to • Connect the K480 control cable from the LN-7 to the 24/42 VAC 14-pin wire feeder amphenol on the the EX350i 115 VAC control cable connector.The front of the EX350i.
  • Page 11: Parallel Operations

    INSTALLATION PARALLEL OPERATION The EX350i are operable in parallel in CC mode. For best results, the currents of each machine should be reasonably well shared. As an example, with two machines set up in parallel for a 400 amp procedure, each machine should be set to deliver approximately 200 amps, not 300 amps from one and 100 amps from the other.
  • Page 12: Operation

    OPERATION SAFETY PRECAUTIONS • After welding, the meter holds the actual current value for 5 seconds. Output adjustment while in the WARNING "hold" period results in the "prior to operation" char- acteristics stated above. The displays blink indicat- ELECTRIC SHOCK can kill. ing that the machine is in the "Hold"...
  • Page 13: Hidden Middle Control Panel

    OPERATION 5. THERMAL CC-STICK SOFT: The Stick Soft process features • This status light indicates when the power source has continuous control ranging from 5 to 425 amps. This been driven into thermal overload. If the output terminals mode was intended for most SMAW applications, and were "ON", the "ON"...
  • Page 14 OPERATION TIG GTAW: The TIG mode features continuous con- • The Hot Start control is not used in the CV-FLUX trol from 5 to 425 amps. The TIG mode can be run in CORED mode. either the TIG touch start or high frequency (optional •...
  • Page 15 OPERATION 7A. ADVANCED PROCESS PANEL • Pulsed Modes (See Figure 2) In Pulse Modes; The work point will be in the Amps window and To program Welding modes. Select knob is used to should be set close to the wire feed speed of the Scroll through all Welding modes.
  • Page 16 OPERATION CONTROLS: 5. After all adjustments have been made press and (See Figure 2) hold the Memory button until the display changes. The right and the left window will display a memory The MEMORY button and SELECT knob are used position, lets say M1(or turn knob to select memory together to select a welding process and store it in of your choice.
  • Page 17 OPERATION WELD MODE DETAILS: Mode Range Comments Stick Soft 5 - 425 amps The stick soft mode is the best selection for general stick applications. Arc Control = Arc Force Hot Start = Initial hot start current (min = start a match set amps, Max. = greatest hot start current) During hot start, arc force is set at high and is fast response.
  • Page 18 OPERATION PULSE PROGRAMS: MODE IMP* COMMENTS .030 Steel 65 - 1200 The EX350i pulse programs are non-synergic and allow indepen- .035 Steel 55 - 800 dent control of the wire feed speed and the arc length. The Output .045 Steel 50 - 700 Control Knob on the EX350i, adjusts an "SPD"...
  • Page 19: Lower Case Panel

    OPERATION LN-10/DH-10 Wire Feeder Compatibility Note: • If a remote control is connected to any of the amphenols the WELD TERMINAL control will The LN-10 and DH-10 feeders can be used to pulse default to REMOTE. If there are not any remote weld and in the power mode with the panel.
  • Page 20: Auxiliary Power

    OPERATION AUXILIARY POWER • 115VAC, 42VAC and 24VAC power is available from the two 14-pin amphenols on the rear of the unit. These supplies are intended to supply power for auxiliary equipment like wire feeders and the TIG Module. • 115VAC supply is rated at 2 amps and is protected by a 2.5 amp breaker located by the amphenol.
  • Page 21: Accessories

    ACCESSORIES QUICK DISCONNECT PLUGS OPTIONS / ACCESSORIES • K2176-1 Twist-Mate to Lug Adapter A quick disconnect system is used for the welding • K1764-1 Inverter and Feeder Cart cable connections. The K852-70 is designed to • K1557 Swivel Kit accept a welding cable size of 1/0 to 2/0. •...
  • Page 22: Maintenance

    MAINTENANCE SAFETY PRECAUTIONS VISUAL INSPECTION WARNING Clean interior of machine with a low pressure air stream. Make a thorough inspection of all compo- ELECTRIC SHOCK can kill. nents. Look for signs of overheating, broken leads or • Do not touch electrically live parts or electrode with skin or wet clothing.
  • Page 23: Troubleshooting

    HOW TO USE TROUBLESHOOTING GUIDE WARNING Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel. Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical Shock, please observe all safety notes and precautions detailed throughout this manual.
  • Page 24: Troubleshooting

    (SYMPTOMS) Major physical or electrical damage 1. Contact your local authorized is evident when the sheet metal Lincoln Electric Field Service facil- covers are removed. ity for technical assistance. Input fuses keep blowing, or input 1. Make certain that the fuses or breaker keeps tripping breakers are properly sized.
  • Page 25 TROUBLESHOOTING Observe all Safety Guidelines detailed throughout this manual PROBLEMS POSSIBLE AREAS OF RECOMMENDED (SYMPTOMS) MISADJUSTMENT(S) COURSE OF ACTION Thermal symbol is lit 1. Check for proper fan operation. If fan is not operating correctly the CB 2 amp breaker may have opened.
  • Page 26: Fault Codes

    TROUBLESHOOTING Observe all Safety Guidelines detailed throughout this manual Fault Codes Code Description Corrective Action Primary over current. If condition persists The machine needs to contact an authorized be turned off and back Lincoln Field Service on to reset the machine. Shop CAP bank A under voltage.
  • Page 27: Displays

    TROUBLESHOOTING Observe all Safety Guidelines detailed throughout this manual Displays Description Scrolling dash Appears at power up while the machine is going through its self configu- ration "Err" "####" Fault code display. The first fault to occur will be displayed for three seconds.
  • Page 28 DIAGRAMS EX350i...
  • Page 29 DIAGRAMS EX350i...
  • Page 30 DIAGRAMS EX350i...
  • Page 31 DIAGRAMS EX350i...
  • Page 32 DIAGRAMS EX350i...
  • Page 33 DIAGRAMS EX350i...
  • Page 34 DIAGRAMS EX350i...
  • Page 35 DIMENSION PRINT EX350i...
  • Page 36 NOTES EX350I...
  • Page 37 Year AMERICAN EXPRESS USE THIS FORM TO ORDER: Order from: BOOK DIVISION, The Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199 for fastest service, FAX this completed form to: 216-361-5901 BOOKS OR FREE INFORMATIVE CATALOGS Telephone: 216-383-2211 or,...
  • Page 38 Do not touch electrically live parts or Keep flammable materials away. Wear eye, ear and body protection. WARNING electrode with skin or wet clothing. Insulate yourself from work and ground. Spanish No toque las partes o los electrodos Mantenga el material combustible Protéjase los ojos, los oídos y el AVISO DE bajo carga con la piel o ropa moja-...
  • Page 39 Keep your head out of fumes. Turn power off before servicing. Do not operate with panel open or Use ventilation or exhaust to guards off. WARNING remove fumes from breathing zone. Spanish Los humos fuera de la zona de res- Desconectar el cable de ali- No operar con panel abierto o AVISO DE...
  • Page 40 • World's Leader in Welding and Cutting Products • • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com...