Table 2- 2
Error Symptoms List
Error Symptoms
Diagnostics programs
cannot be executed.
Missing diagnostic files(s).
Some or all keys on
keyboard do not work.
System unit does not turn
off with power switch.
(System unit must be
unplugged from
electrical outlet to
completely turn off.)
Software shutdown
feature is disappeared
but power supply can
be controlled by power
switch.
No system power, or fan
is not running.
Any other problem.
Action/FRU
Diagnostic Program
Reboot the system from the bootable
Diagnostic diskette.
Diagnostic diskette
Memory module
System board
Diagnostic diskette.
Keyboard
"Keyboard "on page 2-29.
Power Supply
JP20 should be set to "Software
shutdown enabled". See "System
Board Layout" on page 5-2.
"Power Supply" on page 2-32.
Power switch cable assembly
System board
JP20 should be set to "Software
shutdown enabled".. See "System
Board Layout" on page 5-2.
System board.
"Power Supply" on page 2-32.
Power switch assembly.
Power supply.
System board.
Other Problems
"Undetermined Problem" on page 2-45.
Check Procedures
2-23