Permitted ambient conditions
Ambient temperature
Distance from metal
Degree of protection
Resistance to mechanical stress
Design, dimensions and weight
Dimensions (L x W x D)
Weight
The EPC memory has a default size of 96 bits. If necessary, the EPC memory size can be
1)
expanded to 480 bits in increments of 16 bits at the cost of the user memory.
The information relates to the maximum read range. You can find more information on
2)
ranges in the section "Minimum distances and maximum ranges (Page 55)".
For more information, refer to the section "Storage and transportation roll goods
3)
(Page 363)".
When affixed and if the ambient conditions are adhered to (operating temperature -25 ...
4)
+85 °C).

SIMATIC RF600

System Manual, 06/2019, J31069-D0171-U001-A22-7618
In operation, during write/read access
In operation, outside write/read access
During transportation and storage
7.2 SIMATIC RF630L Smartlabel
6GT2810-2AE80-0AX2
-25 ... +85 °C
-25 ... +85 °C
Special feature:
at +130 °C: Storage
retention tested for
30 minutes
+5 ... +25 °C
3)
Not suitable for mounting directly on metal
IP67
4)
Torsion and bending stress conditionally permis-
sible
105 (±1) × 25 (±1) × 0.3
mm
Approx. 1 g
Transponder
6GT2810-2AE81-0AX1
-25 ... +85 °C
-25 ... +85 °C
Special feature:
starting at +140 °C:
No processing pos-
sible
at -40 °C and +160
°C: Storage reten-
tion tested for 90
minutes
90 (±0.5) × 30 (±0.5) ×
0.3 mm