Appendix A. Specifications; A1. Functional; A2. Wireless; A3. Electrical - DSC WP8033 Installer's Manual

Table of Contents

Advertisement

APPENDIX A. Specifications

A1. Functional

Zones Number
Hard-wired Zone Requirements
Maximum Loop Current
Maximum Loop Voltage
Loop Shorted
Loop Normal
Loop Open
Installer and User Codes
Control Facilities
Arming Modes
Alarm Types
Siren Signals
Siren (bell) Timeout
Internal Sounder Output
Supervision
Special Functions
Data Retrieval
Real Time Clock (RTC)
Battery Test

A2. Wireless

RF Network
Frequency bands (MHz)
Hopping frequencies
Region
Encryption

A3. Electrical

External AC/AC adaptor
External AC/DC adaptor
Internal AC/DC
Current Drain
Low Battery Threshold
Backup Battery Pack
20
Up to 64 wireless zones, (including 2 hard-wired inputs).
2.2 kE.O.L. resistance (max. resistance of wires 220 
1.5 mA
3.3 V
0 – 1.47 V (0 – 1.770 Ω)
1.47 – 1.8 V and 2.02 – 2.3 V
2.3 – 3.3 V (5.06 - ∞ Ω)
1 master installer (9999 by default)*
1 installer (8888 by default)*
1 master user, no. 1 (1111 by default)
Users nos. 2 - 48
* Codes must not be identical
-
Integral keypad, wireless keyfobs and keypads
-
SMS commands via optional GSM/GPRS module.
-
Remote control by telephone.
AWAY, HOME, AWAY-INSTANT, HOME-INSTANT, LATCHKEY, FORCED, BYPASS.
Silent, personal panic/emergency, burglary, gas, fire and flood.
Continuous (intrusion / 24 hours / panic); triple pulse – short pause - triple pulse... (fire);
four pulses – long pause – four pulses... (gas);
long pulse – long pause – long pulse... (flood).
Programmable (4 min. by default)
At least 85 dBA at 3 m (10 ft)
Programmable time frame for inactivity alert
- Chime zones
- Diagnostic test and event log.
- Local and Remote Programming over Telephone, GSM /GPRS connections.
- Calling for help by using an emergency transmitter.
- Tracking inactivity of elderly, physically handicapped and infirm people.
- Message center (recording and playback)
Alarm memory, trouble, event log
The control panel keeps and displays time and date. This feature is also used for the log
file by providing the date and time of each event
Once every 10 seconds
PowerG – 2-way synchronized Frequency Hopping (TDMA / FHSS)
433 – 434
8
Worldwide
AES-128
NA
External (wall-mounted) switching power supply 100VAC to 240VAC, 50/60 Hz, 0.5A
/ 12.5 VDC, 1.2A
Internal switching power supply:
Input: 100-240VAC, 0.75A
Output: 12.5 VDC, 1.6A.
Approx. 260 mA standby at the beginning (power ON) and then goes down to 60 mA,
1400 mA max. current drain during alarm.
7.2 V (6-cell battery pack)
9.6 V (8-cell battery pack)
Backup Battery Options:
Maximum external devices current (1)
1300 mAh
6 Battery Pack (2)
4h
180 mA
8h
70 mA
12h
35 mA
24h
max backup w/o
load 22 hours
32h
no backup
39h
no backup
868 - 869
4
Europe and South Africa
1800 mAh
2200 mAh 8-Battery
8-BatteryPack (3)
Pack (4)
300 mA
380 mA
125 mA
160 mA
70 mA
95 mA
12 mA
25 mA
0 mA
10 mA
no backup
0 mA
D-306048
912 - 919
50
North America and
selected countries
WP8033 Installer's Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents