7. Servicing
7.3

Install the re-sync unit

C
AUTION
humidity level inside a sealed tile will damage the internal fans and other electronic parts. Place, if necessary,
some small bags with a liquid absorbing substance (silica gel) inside the tile to absorb the remaining humidity.
C
AUTION
unit is removed. This to ensure a good sealing between the SLite tile and the re-sync unit. To forsake this
instruction will result in internal damage of the SLite tile.
Necessary tools
10 mm nut driver
Necessary parts
New sealing ring (R724571).
Four bolts M6 x 16.
How to install the re-sync unit of an SLite tile ?
1. Place a new sealing ring (O) on the re-sync unit.
Tip:
Use the four bolts (M6 x 16) to keep the sealing ring on its place.
2. Reconnect the internal power cable (P) and data cable (D) with the re-sync unit.
D
P
O
Image 7-3
3. Gently place the re-sync unit into position.
4. Fasten the re-sync unit with four bolts M6 x 16, using a 10 mm nut driver.
38
:
Ensure to perform this procedure in a dry and clean environment with a low humidity level. A high
:
Always replace the old sealing ring of the re-sync unit with a new one for each time the re-sync