3.1.12

CYCLE982 measuring cycle parameters

PROC CYCLE982(INT S_MVAR,INT S_KNUM,INT S_PRNUM,INT S_MA,INT S_MD,REAL S_ID,REAL S_FA,REAL
S_TSA,REAL S_VMS,REAL S_STA1,REAL S_CORA,REAL S_TZL,REAL S_TDIF,INT S_NMSP,INT S_EVNUM,INT
S_MCBIT,INT _DMODE,INT _AMODE) SAVE ACTBLOCNO DISPLOF
Table 3- 12
CYCLE982 call parameters
No. Screen form
Cycle
parameters
parameters
1
S_MVAR
2
Selection
S_KNUM
3
Icon+
S_PRNUM
number
Measuring cycles
Programming Manual, 02/2011, 6FC5398-4BP40-0BA0
1)
Meaning
Measuring version
Values:
UNITS: Calibration/measurement
0 = Calibrate tool probe
1 = Single tool measurement
2 = Multiple tool measurement, determine lengths and tool radius (for milling
tools)
TENS: Calibration or measurement in the MCS or WCS
0 = Machine-related
1 = Workpiece-related
HUNDREDS: Measurement with or without reversal for milling tools
0 = Measurement without reversal
1 = Measurement with reversal
THOUSANDS: Correction target for milling tools
0 = length or length and radius is/are determined (see
1 = radius is determined, if
2 = length and radius are determined (face side), if
23 = disk-type milling tool, upper cutting edge (rear side) and length and
radius are determined
TEN THOUSANDS: Position of the milling tool or the drill
0 = Axial position of the milling tool or the drill, radius in 2nd axis of the plane
(for G18 X)
7)
1 = Radial position of the milling tool or the drill, radius in 1st axis of the plane
(for G18 Z)
7)
HUNDRED THOUSANDS: Incremental calibration or measurement
0 = No specification
1 = Incremental calibration or measurement
MILLIONS: Position spindle at starting angle
of milling tools)
0 = spindle is not positioned
1 = spindle is positioned at the starting angle
Offset variant
2)
Values:
UNITS: Tool offset
0 = No specification (tool offset in geometry)
1 = Tool offset in wear
Number of the field of the probe parameters (not probe number)
(default=1)
3.1 Overview of measuring cycle parameters
3)
4)
1st position = 1
S_MVAR
5)
S_STA1
S_STA1
Parameter lists
1st position)
S_MVAR
1st position = 1 or
S_MVAR
(only for measurement
247