1.7.2
Measuring tools on milling machines, machining centers
Tool probe
Figure 1-4
Tool probes have their own data fields in the general setting data:
● For machine-related measurement/calibration:
● For workpiece-related measurement/calibration:
The triggering points (switching points), upper disk diameter and edge length are entered
here.
Approximate values must be entered here before calibration – if cycles are used in automatic
mode. The cycle will then recognize the position of the probe.
The default setting has data fields for three probes. Up to 99 are possible.
Measuring cycles
Programming Manual, 02/2011, 6FC5398-4BP40-0BA0
Measuring a milling cutter
– SD 54625 $SNS_MEA_TP_TRIG_MINUS_DIR_AX1
– SD 54626 $SNS_MEA_TP_TRIG_PLUS_DIR_AX1
– SD 54627 $SNS_MEA_TP_TRIG_MINUS_DIR_AX2
– SD 54628 $SNS_MEA_TP_TRIG_PLUS_DIR_AX2
– SD 54640 $SNS_MEA_TPW_TRIG_MINUS_DIR_AX1
– SD 54641 $SNS_MEA_TPW_TRIG_PLUS_DIR_AX1
– SD 54642 $SNS_MEA_TPW_TRIG_MINUS_DIR_AX2
– SD 54643 $SNS_MEA_TPW_TRIG_PLUS_DIR_AX2
1.7 Probe, calibration body, calibration tool
Description
23