Cycle976 Measuring Cycle Parameters - Siemens SINUMERIK 840D sl Programming Manual

Measuring cycles
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Parameter lists
3.1 Overview of measuring cycle parameters
3.1.4

CYCLE976 measuring cycle parameters

PROC CYCLE976(INT S_MVAR,INT S_PRNUM,REAL S_SETV,REAL S_SETV0,INT S_MA,INT S_MD,REAL
S_FA,REAL S_TSA,REAL S_VMS,REAL S_STA1,INT S_NMSP,INT S_MCBIT,INT _DMODE,INT _AMODE) SAVE
ACTBLOCNO DISPLOF
Table 3- 4
CYCLE976 call parameters
No. Screen form
Cycle
parameters
parameters
1
S_MVAR
2
Icon+
S_PRNUM
number
3
S_SETV
4
Z0
S_SETV0
S_MA
5
X / Y / Z
224
1)
Meaning
Measuring version (default=1000)
Values:
UNITS: Calibration on surface, calibration sphere or calibration ring
0 = Length on surface with known setpoint
1 = Radius in calibration ring of known diameter (setpoint) and known center
point. 2 = Radius in calibration ring of known diameter (setpoint) and an
unknown center point
3 = Radius and length at the calibration ball
4 = Radius at the edge with known setpoint. Note selection of measuring axis
and measuring direction.
TENS: Reserved
0 = 0
HUNDREDS: Reserved
0 = 0
THOUSANDS: Selection of measuring axis and measuring direction during
calibration.
0 = No specification (no selection of the measuring axis and measuring
direction required)
1 = Specify selection of measuring axis and measuring direction, see
(one measuring direction in a measuring axis)
S_MD
2 = Specify selection of measuring axis, see
a measuring axis)
TEN THOUSANDS: Determination of the positional deviation (probe skew)
0 = Determine positional deviation of the probe
1 = Do not determine positional deviation
HUNDRED THOUSANDS: Paraxial calibration or at an angle
0 = Paraxial calibration in the active WCS
1 = Calibration at an angle
MILLIONS: Determination of tool length during calibration on surface or on
sphere
0 = Do not determine tool length
1 = Determine tool length
Number of the field of the probe parameters (not probe number)
(default=1)
Setpoint
Setpoint of the length for sphere calibration
Measuring axis (number of the axis)
Values: 1 = 1. Axis of the plane (for G17 X)
2 = 2nd axis of the plane (for G17 Y)
3 = 3rd axis of the plane (for G17 Z)
3)
8)
7)
4)
(default=1)
2), 6)
Programming Manual, 02/2011, 6FC5398-4BP40-0BA0
2)
S_MA
(two measuring directions in
S_MA
6)
Measuring cycles
,
2)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumeric 828dSinumerik 840de slSinumerik 828d

Table of Contents