The vertical distance between the mounting holes must consist of sets of three holes
spaced (from bottom to top) 15.9 mm (0.625 in.), 15.9 mm (0.625 in.), and 12.67 mm (0.5
in.) on-center, which makes each three-hole set of vertical hole spacing 44.45 mm
(1.75 in.) apart on center. Rail-mounting holes must be 7.1 mm ± 0.1 mm (0.28 in. ±
0.004 in.) in diameter. Figure A-4 shows the top front specification dimensions.
Hole Diameter =
7.1 +/- 0.1mm
Figure A-4 Rack specification dimensions top front view

Energy management

The Power S822LC servers have features to help clients become more energy efficient.
EnergyScale technology enables advanced energy management features to conserve power
dramatically and dynamically and further improve energy efficiency. Intelligent Energy
optimization capabilities enable the POWER8 processor to operate at a higher frequency for
increased performance and performance per watt, or to reduce dramatically the frequency to
save energy.
56
IBM Power Systems S822LC for High Performance Computing
6.75mm min
15.9mm
15.9mm
12.7mm
15.9mm
15.9mm
12.7mm
450 +/- 0.75mm
Rack Front Opening
465 +/- 0.8mm
Rack Mounting Holes Center-to-Center
Top Front of Rack
Top Front of Rack
6.75mm min
15.9mm
15.9mm
12.7mm
15.9mm
15.9mm
12.7mm