General - Carrier 40WAW007 Installation And Maintenance Instructions Manual

High wall mount indoor unit for single-phase variable refrigerant flow (vrf) systems
Table of Contents

Advertisement

CAUTION
DO NOT re-use compressor oil or any oil that has been
exposed to the atmosphere. Dispose of oil per local codes
and regulations. DO NOT leave refrigerant system open to
air any longer than the actual time required to service the
equipment. Seal circuits being serviced and charge with
dry nitrogen to prevent oil contamination when timely
repairs cannot be completed. Failure to follow these proce-
dures may result in damage to equipment. For information
about replacement oil type and viscosity, see the Single-
Phase VRF Outdoor Unit installation instructions.
UNIT 40WAW
POWER SUPPLY (V-Ph-Hz)
COOLING CAPACITY (Btuh)
HEATING CAPACITY (Btuh)
INDOOR FAN MOTOR
Type
Input (W)
INDOOR COIL
Number of Rows
Fin Spacing (fins/in.)
Fin Type
Tube Diameter, OD (in.)
Tube Type
Number of Circuits
INDOOR AIRFLOW (cfm)
Low
Medium
High
INDOOR NOISE LEVEL (dBA)
Low
Medium
High
UNIT DIMENSIONS (in.)
Width
Height
Depth
PACKING DIMENSIONS (in.)
Width
Height
Depth
NET/GROSS WEIGHT (lb)
REFRIGERANT TYPE
EXPANSION DEVICE
DESIGN PRESSURE, H/L (psig)
REFRIGERANT PIPING (in.)
Liquid Side, OD
Suction Side, OD
CONNECTING WIRING
Power Wiring
Signal Wiring
DRAINAGE WATER PIPE DIAMETER, OD (in.)
LEGEND
EXV
— Electronic Expansion Valve
NEC
— National Electrical Code
The 40WAW high wall mount unit provides an efficient
way to heat or cool a space and an attractive appearance. The
equipment is initially protected under the manufacturer's stan-
dard warranty; however, the warranty is provided under the
condition that the steps outlined in this manual for initial in-
spection, proper installation, regular periodic maintenance, and
everyday operation of the unit be followed in detail. This man-
ual should be fully reviewed in advance before initial installa-
tion, start-up and any maintenance. Contact your local sales
representative or the factory with any questions BEFORE pro-
ceeding.
Table 1 lists physical data for each unit size. See Fig. 1 for
the model number nomenclature. Figure 2 shows the unit di-
mensions.
Table 1 — 40WAW Physical Data
007
7,500
8,500
253
282.5
309
Sized per NEC and Local Codes Based on Nameplate Electrical Data 3 x 14 AWG
2

GENERAL

009
012
208/230-1-60
9,500
12,000
10,900
13,600
AC Motor
35
2
16
Aluminum with Hydrophilic Coating
9
/
32
Copper Tube with Inner Groove
3
282.5
306
347
29
32
35
36
1
11
/
2
9
1
40
/
4
15
3
/
8
1
12
/
2
30/37
R-410A
EXV (Integrated with the Evaporator)
650/250
1
/
4
1
/
2
3-Core Shielded Wire x 20 AWG
3
/
4
015
018
15,000
19,000
17,000
21,000
55
6
444
370.8
506
444
544
506
34
38
40
1
/
42
4
1
12
/
2
9
1
46
/
2
16
3
/
8
1
12
/
2
35/44
3
/
8
5
/
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

40waw00940waw01240waw01540waw018

Table of Contents