Carrier 40SMC009N Installation Manual

Ducted above-ceiling units (cooling only and heat pump) 40smc***n

Advertisement

40SMC---N
INSTALLATION MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 40SMC009N

  • Page 1 40SMC---N INSTALLATION MANUAL...
  • Page 2: Table Of Contents

    IR Remote Control “Room Controller” “Zone Manager” The unit can be used with infrared Remote Control, with the Carrier “Room Controller” or “Zone Manager”. For the installation instructions of the wired remote controls and the remote control refer to the corresponding manuals.
  • Page 3: Dimensions

    048 - 060 1250 1268 1306 1030 40SMC---N 009 - 012 - 018 024 - 028 - 036 165.5 048 - 060 1030 When designin an installation ensure the use of up-to-date drawings available from your local Carrier office. GB - 2...
  • Page 4: Technical Data

    Carrier manufactured units. installation instructions of the external section. Do not connect this unit to any other manufacturer's outdoor unit.
  • Page 5: Warnings: Avoid

    40SMC---N General information • The manufacturer declines any liability for damage resulting Positions to avoid: from modifications or errors in the electrical or refrigerant connections. • Exposure to direct sunlight. Failure to observe the installation instructions, or use of the •...
  • Page 6 40SMC---N Warnings: avoid... E N G L I S H ... connecting condensate piping to sewage system drain without ... exposure to oil vapours. appropriate trap. Trap height must be calculated according to the unit discharge head in order to allow sufficient and continuous water evacuation.
  • Page 7: Installation

    40SMC---N Installation Service area 250 mm Screws-in rod Shoch absorbers Washer Condensate drainage Unit installation All units are provided with an internal condensate drain pan which Insert 4 M8 threaded rods into the celling. Introduce the other end incorporates a drainage tube 20 mm external Ø (009, 012, 018) of the rods through the slots of unit suspension brackets.
  • Page 8: Refrigerant Connections

    40SMC---N Refrigerant connections E N G L I S H Refer to the outdoor unit installation manual for tube sizing, and limitations (slope, length, number of bends allowed, refrigerant charge, etc.). Tubing diameter Liquid Model (Suction) (Discharge) (inches) (inches) 9,52 (3/8") 6,35 (1/4")
  • Page 9: Cooling Only

    • Make ground connection prior to any other electrical Operation of unit on improper line voltage constitutes connections. abuse and is not covered by Carrier warranty. • Make electrical connections between units prior to proceeding to mains supply unit connection.
  • Page 10: Heat Pump

    (mm Model 40SMC009N 4G1,5 Disconnected 3 x 0,75 40SMC012N 4G2,5 H03VV-F 40SMC009N, 40SMC012N Disconnected combined with Multisplit Heat pump 40SMC 009N, 012N Power supply from indoor unit IMPORTANT: Cable must always be placed above cable N N Y O W2 V1 V2 V3 V4 40 41...
  • Page 11 40SMC---N Refrigerant connections Heat pump combined with Multisplit 40SMC 009N, 012N, 018N, 024N Power supply from outdoor unit N N Y O W2 V1 V2 V3 V4 40 41 Interconnection cable (H07 RN-F) Interconnection cable (H07 RN-F) 10 80 10 80 Indoor and outdoor units interconnections (mm Model...
  • Page 12 Power supply Power supply connection to outdoor unit signal Earth Neutral, connection to outdoor unit Signal Electric connections for auxiliary pump installation - 40SMC009N-40SMC012N PUMP SENSOR 230Vac - 3,15 A min L N N O W2 230V-1N-50Hz To make electric connections you need to modify the cables connecting the N or C pole of the terminal block to the J3 pole of the card and insert the pump contact according to the instructions shown in the diagram above.
  • Page 13: Electric Connection

    40SMC---N Electric connection Electric connections for auxiliary pump installation 40SMC018N-40SMC024N- 40SMC028N- 40SMC036N- 40SMC048N- 40SMC060N PUMP SENSOR To make electric connections you need to modify the cables connecting the N or C pole of the terminal block to the J3 pole of the card and insert the pump contact according to the instructions shown in the diagram above.
  • Page 14: Fan Diagrams

    40SMC---N Fan diagrams E N G L I S H 40SMC012N 40SMC009N 170 180 190 40SMC024N 40SMC018N 1 - Super high speed (optional) 2 - High speed 3 - Medium speed 4 - Low speed Air flow (l/s) GB - 13...
  • Page 15 40SMC---N Fan diagrams 40SMC028N 40SMC036N 40SMC060N 40SMC048N 800 850 900 1 - Super high speed (optional) 2 - High speed 3 - Medium speed 4 - Low speed Air flow (l/s) GB - 14...
  • Page 16 L010127H27 - 1205 Via R. Sanzio, 9 - 20058 Villasanta (MI) Italy - Tel. 039/3636.1 The manufacturer reserves the right to change any product specifications without notice. December, 2005. Printed in Italy...