Technical Data - Studer Xtender XTH 5000-24 Installation And Operating Instructions Manual

Unit combining inverter, battery charger and transfer system
Hide thumbs Also See for Xtender XTH 5000-24:
Table of Contents

Advertisement

STUDER Innotec

18 Technical data

Model
Inverter
Rated battery voltage
Input voltage range
Continuous power @ 25 °C
Smart boost power
30 minute load @ 25 °C
5 second load @ 25 °C
Maximum load
Maximum asymmetrical load
Load detection (standby)
Admissible cos phi
Maximum efficiency
Open-circuit power OFF/standby/ON 1.3W/2.2W/14W 1.8W/2.5W/18W 2.2W/3W/22W 2.2W/3.8W/26 W
Output voltage
Output frequency
Harmonic distortion
Overcharge and short-circuit
Overheating protection
Battery charger
6-phase battery charger
Adjustable charge current
Input current sharing system
Maximum input voltage
AC input voltage range
Admissible input frequency
(PFC)
Battery control (factory value / adjustable range with RCC-02)
End of absorption
Absorption voltage
Periodic absorption voltage
Floating voltage
Reduced maintenance voltage
Equalisation
End of equalisation
Equalisation voltage
Low voltage disconnection
Reduced floating duration
Periodical absorption
Temperature compensation
General data
Auxiliary contacts
Maximum transfer relay current
Maximum transfer time
Weight
Dimensions: H x W x D [mm]
Protection degree
Conformity
Operating temperature range
Ventilation
Noise level
Warranty
Options
Battery temperature sensor:
Remote control and programming centre for wall mounting: RCC-02
Remote control and programming centre for panel mounting: RCC-03
Installation and operating Instructions
XTH 3000-12 XTH 5000-24 XTH 6000-48 XTH 8000-48
12 V
24 V
9.5 - 17 V
19 - 34 V
2500 VA
4500 VA
3000VA
5000 VA
3000 VA
5000 VA
93%
94%
Sine wave 230 Vac (+/-2%) / 180-245 Vac
50 Hz adjustable 45-65 Hz +/- 0.05% (quartz-controlled)
Automatic disconnection then 2 startup attempts
Alarm prior to disconnection and automatic restart
Programmable I-U-Uo-equalisation-Uo(low)-U(periodic)
0 - 140 A
0 - 160 A
Level of detection adjustable from 150 to 230 Vac
by duration: 2h / 0.25 - 18 h or by current <10A / 2 - 50 A
14.4V / 9.5-18 V 28.8V / 19-36 V
- / 9.5 - 18 V
- / 19 - 36 V
13.6V / 9.5-18 V 27.2V / 19-36 V
- / 9.5 - 18 V
- / 19 - 36 V
By number of cycles ( - / - 100) or at fixed intervals ( - / 52 weeks)
By duration 2h / 0.25 – 10h or by current - / 5 – 50 A
- / 9.5 - 18 V
- / 19-36 V
10.8V / 9.5-18 V 21.6V /19-36 V
-5 / 0 to-8 mV/°C/cell (optional BTC-01)
2 independent contacts 16 A - 250 Vac (potential-free 3 points)
34 kg
40 kg
EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022, EN 61000-3-2,
Dir. 89/336/EEC, LVD 73/23/EEC
<40 dB / <50 dB (without / with ventilation)
BTS-01
Xtender V1.3
48 V
38 - 68 V
5000 VA
6000 VA
6000 VA
3 x Pcont
Up to short-circuit
Up to Pnom
2 to 25 W
0.1 – 1
96%
<2%
0 - 100 A
1 - 50 A
265 Vac
45 - 65 Hz
EN 61000-3-2
57.6V / 38 - 72 V
- / 38 - 72 V
54.4V / 38 - 72 V
-- / 38 - 72 V
- / 38 - 72 V
43.2V / 38 - 72 V
- / 0 - 32 days
- / 0 - 10 hours
50 A
0-15 ms
42 kg
230x300x500
IP20
-20 to 55 °C
Forced from 45 °C
2 years
Xtender
48 V
39 - 68 V
7,000 VA
8000 VA
8000 VA
96%
0 - 120 A
46 kg
Page 36