Specification; Wiring - SMC Networks EX500 Series Instruction Manual

Reduced wiring system cc-link compatible gw unit
Hide thumbs Also See for EX500 Series:
Table of Contents

Advertisement

Specification

Basic specifications
Rated voltage
DC24V
Range of power
Power supply for input and controlling GW/SI: DC24V 10%
supply voltage
Power supply for output: DC24V+10%/-5% ( Voltage drop
warning at around 20V )
Rated current
Power supply for input and controlling GW/SI: 3.0A
(
Inside GW unit: 0.2A
Input device and SI control section: 2.8A
Power supply for solenoid valves and output: 3A
Number of input/
Input point: max. 64/Output point: max 64
output points
Higher-level bus
Compatible system
CC-Link Ver.1.10 ( Note )
Number of stations occupied
3 stations
Station type
Remote device station
Transmission speed
156kbps
Cable length between stations
20cm or more
Maximum extended cable length
1200m
Note: The data shown above are those when all devices, cables, etc. are Ver. 1.10- compati-
ble. For other connection and details, please contact CC-Link Partner Association.
Lower-level bus
Number of branches for
4 branches ( 16 points/branch ) for input
input/output
4 branches ( 16 points/branch ) for output
Communication method
Protocol: Dedicated for SMC
Speed:
Branch current for input
Max. 0.5 [A] per branch ( when SI unit and input
( Note )
devices are connected )
Branch current for output
Max. 0.65 [A] per branch
( when SI unit EX500-S
Max. 0.75 [A] per branch
( when SI unit EX500-Q
Branch cable length
5m or less per branch
( total extended length: 10m or less )
Note: Total value of maximum current consumption and maximum load current of input devices
to connect.
8
)
625kbps
2.5Mbps
5Mbps
10Mbps
900m
400m
160m
100m
750kbps
01 is connected )
is connected )

Wiring

Internal circuit
IN
SLD
1
Bus
DB
2
adapter
DG
3
DA
4
OUT
Power supply
0V
1
for output
+24V
2
Power supply
0V
3
connector
Power supply
+24V
4
for input and
PE
5
controlling GW/SI
The wirings are described in the following order.
Communication wiring: Connection with CC-Link line
Power supply wiring: Connections of power supplies for solenoid
valves/output devices, and for input
devices and controlling GW/SI
Branch wiring: Connection from GW unit to SI unit or Input unit
RD+
1
RD -
2
TD+
3
4
TD -
5
+24V
6
0V
+24V
7
DC-DC
0V
8
converter
(insulation)
1
RD+
2
RD -
3
TD+
4
TD -
+24V
5
0V
6
+24V
7
0V
8
COM A
COM D
9