Specification - SMC Networks EX500 Series Instruction Manual

Reduced wiring system cc-link compatible gw unit
Hide thumbs Also See for EX500 Series:
Table of Contents

Advertisement

Wiring ( continued )
Power supply wiring
When combining EX9-OEP1 ( or EX9-OEP2 ) and EX9-PE1 and using external power
supply, connect the power supply to the power input connector of EX9-PE1.
When selecting power supply, refer to "Handling precautions" ( page 3 ) in this manual.
EX9-PE1 power supply connector No.0
M12, 5-pin, reverse key, socket
Keep the waterproof cap mounted on power supply connector No.0 while using
Note
EX9-PE1. This connector is prepared supplementarily and not used normally.
EX9-PE1 power input connector No.1
M12, 5-pin, reverse key, plug
Cable side: Hans Turck GmbH & Co., WAKW series
43
2
5
3
Power input
connector No.1
Pin No.
Power input connector No.1
1
Power supply for output devices ( DC24V )
2
Power supply for output devices ( 0V ) [Power supply for output devices ( 0V ) ]
3
[Power supply for sensor ( DC24V ) ]
4
[Power supply for sensor ( 0V ) ]
5
Ground
Note: Each signal of connector No.0 is connected to corresponding signal of connector No.1.
The pins whose applications are shown in brackets [ ], are prepared supplementarily
and not used normally.
36
4
3
1
5
2
M12
25.5
1
1
2
5
4
4
3
Power supply
connector No.0
Power supply connector No.0
Power supply for output devices ( DC24V )
[Power supply for sensor ( DC24V ) ]
[Power supply for sensor ( 0V ) ]
[Ground]

Specification

1. EX9-OET1/EX9-OET2/ EX9-OEP1/EX9-OEP2
Item
Model No.
EX9-OET1
EX9-OET2
No. of output
points
Output
P-ch MOS-FET
N-ch MOS-FET
method
( open drain )
( open drain )
Insulation
Optical isolation ( with SI unit )
method
Note: To be used in combination with EX9-PE1.
For detailed specifications, refer to the instruction manuals, technical data, etc. of EX9
series general purpose output block.
2. EX9-PE1
Item
Specification
Rated voltage
DC24V+10%, -5%
Supply current
3A Max.
Specification
EX9-OEP1
EX9-OEP2
2 points/unit
P-ch MOS-FET
N-ch MOS-FET
( open drain )
( open drain )
Optical isolation ( with this unit )
( Note )
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ex500-gmj1

Table of Contents