Input Unit Manifold Part Names; Dimensions - SMC Networks EX500 Series Instruction Manual

Reduced wiring system cc-link compatible gw unit
Hide thumbs Also See for EX500 Series:
Table of Contents

Advertisement

Input Unit Manifold Part Names

The Input unit manifold consists of Input unit, input block (s), end block and DIN rail.
Up to 8 of the input blocks can be connected ( 16 points ).
Any combination of input blocks ( for M8 connector, M12 connector and 8-point-
integrated type ) is acceptable.
Note
Do not mix sensor input specifications ( PNP and NPN ) .
Figure shows the configuration when only input blocks for M8 connector are connected.
No.
Part name
1
Input unit
Unit to communicate with GW unit or SI unit.
2
Communication
To be connected with branch cables from GW unit or
connector
SI unit ( branch cable with M12 connector ) ( Note1 )
3
Power LED
Indicates the power supply status. ( Note2 )
4
Input block
Unit for sensor signal input.
5
Sensor connector
Connects with sensor. ( Note1 )
6
Indicator LED
Indicates sensor signal status. ( Note2 )
7
Marker
To be used for writing input No. etc.
8
End block
Completes the end of Input unit manifold.
9
DIN rail
To be mounted with Input unit manifold.
Note1: For wiring method, refer to subsection "Wiring" ( page 30 ) of section "Input Unit
Manifold" in this manual.
Note2: For display, refer to "Display" ( page 31 ) in section "Input Unit Manifold" in this manual.
26
Application
Dimensions ( unit: mm )
When only input blocks for M8 connector are connected
L3
L2 ( Rail mounting pitch: 12.5 )
L1
Stations
1
L1 [mm]: Rail length
98
110.5
L2 [mm]: Mounting pitch
87.5
100
L3 [mm]: Manifold length
74
86
L4 [mm]
12
12
When only input blocks of 8-point-integrated type are connected
Stations
L1 [mm]: Rail length
135.5
L2 [mm]: Mounting pitch
125
L3 [mm]: Manifold length
110
L4 [mm]
12.5
DIN Rail
(L4)
5
2
3
4
5
6
123
135.5
148
160.5
173
112.5
125
137.5
150
162.5
98
110
122
134
146
12.5
12.5
13
13
13.5
1
2
185.5
175
158
13.5
7
8
185.5
175
158
13.5
27