1.8/132 kW TSI; 2.0/162 kW TSI engines - Edition 01.2015
♦ Guide bushing - T20097-
♦ Protective goggles
♦ Protective gloves
Removing
Gearbox removed
– Remove the two-mass flywheel
– Unhook intermediate plate at the sealing flange on the gear‐
box side and dowel sleeves -arrows-.
– Undo screws -1 ... 8-.
– Press sealing flange on the gearbox side.
Install
WARNING
Wear protective gloves when working with sealant and grease
remover!
– Clean sealing surface on cylinder block and on the upper part
of the oil pan and remove sealant residues with chemical seal‐
ant remover.
– Degrease the sealing surfaces.
– Cut off nozzle on tube at front marking (∅ of nozzle approx. 2
mm).
58
Rep. gr.13 - Crankshaft group
⇒ page 56
.