H5AN
Specifications
Ratings
Item
Rated supply voltage
Operating voltage range
Power consumption
Resetting system and
gate input
One-shot output time
Control outputs
Power supply for
externally connected
components
Note: Inrush current was measured within the range shown below.
Peak value
Characteristics
Accuracy of operating time
Setting error
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Approved standards
Weight
Note: This value denotes the average of the repeat accuracy, setting error, and variations due to voltage and temperature changes. It in-
cludes the rise time of the power supply, and the operating time of the internal and output circuits.
2
H5AN-4D:
100 to 240 VAC (50/60 Hz),
12 to 24, 48, or 100 VDC (permissible ripple: 20% max.)
H5AN-4DM: 100 to 240 VAC (50/60 Hz)
12 to 24 VDC (permissible ripple: 20% max.)
85% to 110% of rated supply voltage
Approx. 10 VA (at 240 VAC, 50 Hz), approx. 5 W (at 24 VDC)
Reset by power-OFF: min. power OFF time: 0.5 s
External reset or gate (common to contact and solid-state inputs): min. reset input signal width: 0.02 s
0.1 to 1 s (adjustable)
Contact output: SPDT, 3 A at 250 VAC, resistive load (cosφ = 1)
Solid-state output: Open collector, 100 mA max. at 30 VDC max.
12 VDC±10%, 80 mA (permissible ripple: 5% max.)
Measurement
time
Time
±0.01% ±0.05 s max. (power OFF start), ±0.005% ±0.03 s max. (reset start) (see note)
100 MΩ min. (at 500 VDC) (between current-carrying terminal and exposed non-current
carrying metal parts, between non-continuous contacts)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying metal
parts)
750 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Destruction: 10 to 55 Hz with 0.75-mm double amplitude
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude
Destruction: 300 m/s
Malfunction: 100 m/s
Operating: –10°C to 55°C
Storage:
–25°C to 65°C
Operating: 35% to 85%
Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h)
Electrical:
100,000 operations min. (3 A at 250 VAC, resistive load)
UL (File No. E41515), CSA (File No. LR22310)
Approx. 360 g
H5AN-4D/H5AN-4DM
2
(approx. 30G)
2
(approx. 10G)
H5AN