Positioning The Battery Charger - KTM Freeride E-SM 2016 Setup Instructions

Table of Contents

Advertisement

4
SERVICE WORK
4.10
Locking the seat
4.11
Unlocking procedure for KTM PowerPack
4.12

Positioning the battery charger

Warning
Risk of injury There is a risk of electric shock in a moist environment.
The battery charger is not waterproof.
Only use the battery charger in dry conditions.
Ensure that no fluids flow or drip onto the battery charger.
Warning
Risk of injury If the battery charger is used incorrectly, its intrinsic safety cannot be guaranteed.
The battery charger is only suitable for use with a KTM PowerPack.
Only use the battery charger with a KTM PowerPack.
Only operate the battery charger using household sockets with an earth conductor.
Do not use any additional adapters or extensions.
Follow the applicable safety instructions of the power connection.
Fold down the seat and push it down.
The seat engages with an audible click.
Finally, check that the seat is correctly locked.
C00804-01
Condition
The KTM PowerPack has been removed.
Connect diagnosis cable to the KTM PowerPack.
AVL DiTEST adapter cable (70029069000)
Connect the diagnostics tool and start it.
Ensure external power supply for VCI using 12 V battery.
Blue LED on VCI lights up.
Connect battery charger to the 12 V battery.
Choose vehicle in the diagnostics tool and select "AutoScan".
Execute "Battery management" > "Functions" > "Activate / deactivate transport mode".
Install the KTM PowerPack.
Connect the diagnostics tool and start it.
Clear the fault memory using the KTM diagnostics tool.
Read out the fault memory using the KTM diagnostics tool.
»
When fault memory is empty:
DC 12 V
work is complete.
402173-51
(
p. 18)
13