3
SPECIFICATIONS
3 - 8
4)
Solder the contact to the internal conductor.
5)
Insert the connector assembly shown in (4) into the plug shell and
screw the nut into the plug shell.
POINT
(1) Note the following precautions when soldering the internal conductor and
contact.
• Make sure that the solder does not bead up at the soldered section.
• Make sure there are no gaps between the connector and cable insulator or
they do not cut into each other.
• Perform soldering quickly so the insulation material does not become
deformed.
(2) Before connecting or disconnecting the coaxial connector, touch a grounded
metal object to discharge the static electricity from the human body. Failure to
do so may result in a module malfunction.