Operation Site
4.8.3
Connection of an Exhaust on the Laser Exhaust Duct
(only for machines with gaslaser)
Applies only to d-lab.2 type 8060/260 and d-lab.2plus type 8060/261
not applicable for machines with solid state laser
(d-lab.2 type 8060/803, 8060/804, 8060/270, 8060/272 und 8060/157+8060/255,
d-lab.2plus type 8060/813, 8060/814, 8060/271, 8060/273 und 8060/158+8060/255)
netlab.2plus type 8060/505)
7
6
4
G_GG402
The fan of the laser power supply generates an air stream of 220 m³/h.
An exhaust hose can be connected on rectangular connection piece (5) located on the
Printer rear panel.
An adapter for the connection to an air exhaust hose with a diameter of 125 mm is
available:
Type 8060/350, order number (ABC-Code) 5GVP2.
CAUTION!
Never use an exhaust hose smaller than 125 mm in diameter. This would cause
heat accumulation resulting in a reduced life span of the laser!
Note
The wet section of the Paper Processor is sealed. The exhaust air generated here is
negligible. Hence, the connection of an air exhaust is not necessary in this area.
12
2005-05-01 / PN 04100_01
5
3
3
1
2
d-lab.2, d-lab.2plus, netlab.2plus: Preinstallation
1 Air supply for Printer power supply
2 Exhaust laser and Printer power supply
3 Air supply laser
4 Air supply Printer
5 Exhaust laser
6 Exhaust Printer
7 Exhaust Paper Processor
Pos. 3 and 5 are omitted in machines with solid state
lasers