Contactor Coil And Mov Check - Southbend EZ-3/EZ-5 Operator's Manual

Simple steam countertop steamers
Table of Contents

Advertisement

T
ROUBLESHOOTING
Figure 13

Contactor Coil and MOV Check

C
B
A
1. Disconnect power at circuit breaker.
2. Remove control panel and disconnect nine-pin plug PL1.
3. Depress actuator on top of contactor. Actuator should travel freely and spring back when released.
4. Check for continuity between contacts A and D as shown in top view. There should be no continuity.
5. Repeat Step 4 for contacts B and E and for contacts C and F.
6. Place test leads on contactor coil terminal as shown in left side view.
7. Check resistance.
8. If resistance is not approximately 390 (+/- 40) ohms, remove MOV and recheck coil resistance. If
resistance is now approximately 390 (+/-40) ohms, replace MOV, otherwise replace contactor.
9. Reconnect all wires.
P
24
AGE
Actuator
F
E
D
TOP VIEW
M
EZ-3 & EZ-5 C
ODEL
MOV
LEFT SIDE VIEW
O
'
M
1178387
PERATOR
S
ANUAL
S
OUNTERTOP
TEAMERS
5
REV

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ez-3Ez-5

Table of Contents