the knob 30, the time is set up in seconds either to reach
the final current welding in the Four Times mode, or to
cancel the nominal current welding in the Two Times
mode.
The frequency can be regulated between the following
ranges:
Between 0,3 Hz and 1Hz with a 0,1 Hz step.
Between 1 Hz and 250Hz with a 1 Hz step.
Descent Slope
By pressing function keys 31 e 32 the luminous indicator
is position at 27 - Picture 1 Page 6.); then by activating
the knob 30, the time is set up in seconds either to reach
the final current welding in the Four Times mode, or to
cancel the nominal current welding in the Two Times
mode.
The value range is between 0 and 10 seconds.
Final Current
By pressing function keys 31 e 32 the luminous indicator
is position at 28 - Picture 1 Page 6.); then by activating
the knob 30, the value for the final current on the TIG
Four Times mode is set up. The value range is between
I Min and the nominal current welding.
Post gas
By pressing function keys 31 e 32 32 the luminous
indicator is position at 29 - Picture 1 Page 6.) then by
activating the knob 30, the time length for the final gas
flux is set up in seconds. The value range is between 0,2
and 20 seconds.
English
Four times functionality for TIG welding
The generator allows a management of the Four Times
26
Intelligent mode. In fact, it is possible to modify the
automatic sequence depending on how the torch button
is used (See picture).
The current's descent slope is also possible from the
reduced current.
Pressure without the torch button release.
Torch button release.
Pressure and immediate release of the torch
button.
27
Release and immediate pressure of the torch
button.
28
9
29