Menu items in the range 100 to 199, relating to the control panels (Continued)
Item number Item name
135
TELE-FILE THREAD
COUNTER CLEAR MODE
136
TELE-FILE IN OUT INPUT
CONTINUE
139
LOST LOCK DISPLAY ON
CONTROL PANEL
Menu items in the range 200 to 299, relating to the remote control interface
Item number Item name
PARA RUN
201
202
CF FLAG (Valid only in
50i or 25PsF mode)
211
REMOTE1 PORT
212
VIDEO REMOTE
CONTROL SELECT
(Invalid in 24PsF or
23.98PsF mode)
Sub-item
1
IMAGE
ENHANCER
2
D2 SETUP
Settings
Select whether to clear the thread counter when formatting a Tele-File.
[NOT CLEAR]: Do not clear the thread counter.
WHEN FORMAT: Clear the thread counter.
Select whether to continuously input log (IN and OUT point) data in the Tele-File
menu screen.
[OFF]: Do not continuously input log (IN and OUT point) data.
ON: Continuously input log (IN and OUT point) data.
Select whether or not to display a "LOST LOCK" indication on the control panel
when the lock is lost.
[OFF]: No display on control panel for LOST LOCK.
ON: Display on control panel for LOST LOCK.
Settings
Select whether or not to use synchronized operation for two or more VTRs.
[DIS]: No synchronized operation
ENA: Use synchronized operation
Note
To use synchronized operation for two or more VTRs, set item 201 to "ENA" on
all of the VTRs.
Select the mode for locking to the color framing sent from the remote controller.
[8F]: Eight-field locking mode
4F/8F: Four- or eight-field locking mode
Select how to use the REMOTE 1-IN(9P) and REMOTE 1-OUT(9P) connectors
on the connector panel.
: Both the IN and OUT connectors are effective whether in local or remote
I&O
mode.
IN: Only the IN connector is effective whether in local or remote mode.
OUT: Only the OUT connector is effective whether in local or remote mode.
PANEL: Allows you to select I&O, IN, or OUT using the function menu.
Note
When selecting "PANEL", first define user-defined function key RMT1 in the
HOME2 page.
On how to define user-defined function keys in the HOME2 page, refer to the
Maintenance Manual Volume 1.
Make settings for control from HKDV-900/503 via the VIDEO CONTROL (15P)
connector.
Select whether to control the up-converter or down-converter whether controlling
the image enhancer.
[down]: Control the down-converter.
up: Control the up-converter.
u&d : Control both the up-converter and down-converter.
Select the menu item to be controlled by the SETUP dial on the HKDV-900/503
with the D2 button pressed.
[setup]: Sub-item (OUTPUT LEVEL) of menu item 713 (VIDEO SETUP
REFERENCE LEVEL)
Black : Menu item 718 (SETUP LEVEL)
For details, see the description of menu item 718.
Note
After changing the setting for this item, power off this unit or HKDV-900/503 and
power it on again.