8.9.3

200- -240-Volt Configurations

The 200--240-volt configuration does not use a jumper
lead. If the unit was originally wired for straight 100--120
volt, 3-wire, remove the jumper lead (see Figure 8-18 for
location). See Figure 8-21.
L0 (Neutral)
Ground
Load
Side
Line
Side
4
1
3
2
Stator Leads
60 Hz
L0--L1
200-240 Volt 200--220--240 Volt
Figure 8-21 200--220--240-Volt, 2-Wire Configuration
for Models with ADC 2100
115/230
Note: Current Transformers (CTs) are not used on all sets. CT dot or "HI" toward generator.
Figure 8-22 Generator Reconnection
TP-6255 7/06
L0
GRD.
L1
Single-Pole
Circuit
Breaker
Tape to insulate
from ground
200- -220- -240 Volt
2 Wire
50 Hz
115/230

8.10 Twelve-Lead Reconnection

The reconnection procedure following details voltage
reconnections only.
If the generator set requires
frequency changes, adjust the governor.
The following information illustrates the reconnection of
12-lead generator sets. In all cases, follow the National
Electrical Code (NEC) guidelines.
Reconnect the stator leads of the generator set to
change output phase or voltage. Refer to the following
procedure and connection schematics. Follow all safety
precautions at the front of this manual and in the text
during reconnection procedure.
NOTICE
Voltage reconnection. Affix a notice to the generator set after
reconnecting the set to a voltage different from the voltage on
the nameplate. Order voltage reconnection decal 246242
from an authorized service distributor/dealer.
Twelve-Lead Reconnection Procedure
1. Move generator set master switch to OFF/RESET
position.
2. Disconnect engine starting battery, negative (--)
lead first. Disconnect power to battery charger, if
equipped.
3. Use Figure 8-22 to determine generator set
voltage configuration. Note the original voltage
and reconnect the generator set as needed.