Samsung NY36R9966P Installation Manual
Samsung NY36R9966P Installation Manual

Samsung NY36R9966P Installation Manual

Dual fuel pro range
Hide thumbs Also See for NY36R9966P:

Advertisement

Dual Fuel Pro Range
Installation manual
NY36R9966P*
Install_NY9900R_CHEF_NY36R9966PS_AA_DG68-01106B-01_EN+MES+CFR.indb 1
2019-03-14
3:55:49

Advertisement

Table of Contents
loading

Summary of Contents for Samsung NY36R9966P

  • Page 1 Dual Fuel Pro Range Installation manual NY36R9966P* Install_NY9900R_CHEF_NY36R9966PS_AA_DG68-01106B-01_EN+MES+CFR.indb 1 2019-03-14 3:55:49...
  • Page 2 ANTI-TIP DEVICE WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal WARNING injury or death. • DO NOT store or use gasoline or other flammable vapors and ALL RANGES CAN TIP, RESULTING IN PERSONAL INJURY. liquids in the vicinity of this or any other appliance.
  • Page 3: Table Of Contents

    Contents Before you begin Installation requirements About this manual Location requirements Installation guide Important safety information To remove safely from the pallet Read all instructions before using this appliance To avoid breakage Symbols used in this manual Gas requirements California Proposition 65 Warning Special gas requirements (gas models sold in Massachusetts) Commonwealth of Massachusetts Electrical requirements...
  • Page 4: Before You Begin

    Before you begin Important safety information About this manual Read all instructions before using this appliance Read these instructions completely and carefully. • All electrical and gas equipment with moving parts can be dangerous. Please read the important safety instructions for this appliance in this manual. The Important note to the installer instructions must be followed to minimize the risk of injury, death, or property damage.
  • Page 5: California Proposition 65 Warning

    California Proposition 65 Warning • Remove all packaging materials from the range before operating to prevent ignition of these materials. Keep all packaging materials out of children’s reach. Properly dispose the packaging materials after the range is unpacked. WARNING • Do not store any object of interest to children on the cooktop or backguard Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
  • Page 6: Fire Safety

    Important safety information Fire safety Gas safety WARNING WARNING To reduce the risk of fire, electric shock, personal injuries, and/or death, obey the To reduce the risk of fire, electric shock, personal injuries, and/or death, obey the following precautions. following precautions. •...
  • Page 7: Electrical And Grounding Safety

    Electrical and grounding safety Installation safety WARNING WARNING To reduce the risk of fire, electric shock, personal injuries, and/or death, obey the To reduce the risk of fire, electric shock, personal injuries, and/or death, obey the following precautions. following precautions. •...
  • Page 8: Location Safety

    Important safety information Location safety • Make sure your range is correctly installed and adjusted by a qualified service technician or installer for the type of gas (natural or LP) you will use. For your range to utilize LP gas. The installer must replace the 6 surface burner WARNING orifices with the provided LP orifice set.
  • Page 9: Cooktop Safety

    Cooktop safety • To avoid cookware discoloration, deformity, and/or carbon monoxide poisoning, do not use cookware that is exceedingly larger than the grate. Make sure cookware handles are turned to the side or rear of the cooktop, but • WARNING not over other surface burners.
  • Page 10: Oven Safety

    Important safety information Oven safety Self-cleaning oven safety WARNING WARNING To reduce the risk of fire, electric shock, personal injuries, and/or death, obey the To reduce the risk of fire, electric shock, personal injuries, and/or death, obey the following precautions. following precautions.
  • Page 11: Gas Range Components

    Gas range components Overview Cooktop Burner Placement Location Output Rating (Natural Gas) Left-Front (LF) 22,000 BTU MODEL NY36R9966P* Left-Rear (LR) 16,000 BTU Right-Front (RF) 22,000 BTU Right-Rear (RR) 16,000 BTU Center-Front (CF) 16,000 BTU Cooktop Burners (under grates) Burner Center-Rear (CR)
  • Page 12 Gas range components Without grate 36" (91.4 cm) Min. 37 ¼" (94.6 cm) Max. With grate " (94.9 cm) Min. " (98.1 cm) Max. 35 ⅞" (91.1 cm) 12 English Install_NY9900R_CHEF_NY36R9966PS_AA_DG68-01106B-01_EN+MES+CFR.indb 12 2019-03-14 3:55:51...
  • Page 13: Installation Requirements

    Installation requirements Location requirements 13 in (33 cm) 30 in (76.2 cm) Clearances and dimensions Overhead Cabinet Depth 36 in NOTE (914 mm) • For OTR over Gas Stove, please follow local GAS CODE. 30 in (76.2 cm) 6 in* 6 in* 18 in •...
  • Page 14: Installation Guide

    Installation requirements Installation guide Minimum dimensions CAUTION Recommended locations for gas piping and electrical outlets • If overhead cabinets are installed, a range hood should also be installed and project horizontally a minimum of 5" (12.7 cm) beyond the front of the cabinets.
  • Page 15: To Remove Safely From The Pallet

    To remove safely from the pallet To avoid breakage Remove the screws from the bottom CAUTION bracket on either side of the unit. • Please DO NOT push the unit strongly when you install. These actions can cause the damage to the unit. Press the bracket on either side to pull •...
  • Page 16: Gas Requirements

    Installation requirements Gas requirements The counter top around the cut-out should be flat and leveled (see hatched area on Fig. 1). Provide adequate gas supply Before installing the unit, measure the This range is designed to operate at a pressure of 5 in (13 cm) of water column on heights of the two cabinet sides (C1–...
  • Page 17: Special Gas Requirements (Gas Models Sold In Massachusetts)

    Special gas requirements (gas models sold in Massachusetts) Electrical requirements WARNING COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS: To reduce the risk of fire, electric shock, or personal injury: WARNING All ranges • Gas leaks may occur in your system, creating a dangerous situation. Gas leaks may not be detected by smell alone.
  • Page 18 Installation requirements Grounding Usage situations where appliance power cord will be disconnected frequently • All ranges must be grounded for personal safety. Do not use an adapter plug in these situations because disconnecting of the power • All gas models have a power cord with an equipment-grounding conductor cord places under strain on the adapter and leads to eventual failure of the adapter and a grounding plug.
  • Page 19: Tools And Materials

    Tools and materials What’s in the box Parts needed Parts supplied Flexible metal 4-wire cord or Gas line Flare union adapter appliance connector 3-wire cord shut-off valve ¾" or ½" (NPT) x ½" (ID) ½" (ID) x 5 ft Surface burner grates (3) Surface burners and caps (6) Flare union adapter 135-degree elbow...
  • Page 20: Installation Instructions

    Installation instructions Installation instructions Installing your Dual fuel Range Step 2. Meeting electrical connection requirements CAUTION NOTE For personal safety, do not use an extension cord with this appliance. Remove • IMPORTANT: Please read the following instructions, as well as the Important house fuse or open circuit breaker before beginning installation.
  • Page 21 A 50 amp range cord is not recommended but if used, it should be marked for Specified power-supply-cord kit rating use with nominal 1⅜" diameter connection openings. Care should be taken to Diameter (inches) of range center the cable and strain relief within the knockout hole to keep the edge from Range rating, watts Specified rating connection opening...
  • Page 22 Installation instructions Installing a 3-wire power cord Installing a 4-wire power cord WARNING WARNING The neutral or ground wire of the power cord must be connected to the neutral The neutral wire of the supply circuit must be connected to the neutral terminal terminal located in the center of the terminal block.
  • Page 23 Step 5. Installing the conduit Installing a 3-wire conduit • Aluminum building wire may be used but it must be rated for the correct Remove the conduit connection plate from the rear of the drawer body and rotate amperage and voltage to make the connection. Connect wires according to it as shown below.
  • Page 24 Installation instructions Installing a 4-wire conduit Step 6. Replacing the access cover • Aluminum building wire may be used but it must be rated for the correct Replace the access cover on the range back. To replace the wire cover, insert amperage and voltage to make the connection.
  • Page 25 Step 7. Connect the range to gas supply Install male 0.5-in (1.3-cm) flare union adapter to the 0.5-in (1.3-cm) NPT internal thread at the regulator inlet. Use a backup wrench on the regulator Shut off the main gas supply valve before disconnecting the old range and leave fitting to avoid damage.
  • Page 26 All new gas ranges are shipped from the factory set up to use natural gas. Any Do not exceed 25 ft-lbs of torque when making gas line connections. Samsung gas range can be converted to use LP gas. (Contact a qualified service Overtightening may crack the pressure regulator resulting in gas leak.
  • Page 27 Step 9. Install the anti-tip device *approximatel WARNING Anti-Tip ” (35.1 mm) bracket • To reduce the risk of tipping, the appliance must be secured by properly installing the anti-tip device packed with the appliance. All ranges can tip, resulting in personal injury. •...
  • Page 28 Installation instructions Step 10. Plug in and place Step 11. Moving and placing the range Due to the weight, heavy equipment WARNING movers such as Air Sled should be used • BEFORE OPERATING OR TESTING, follow the grounding requirements on pages to move this unit.
  • Page 29 Place the left and right surface burner After installing and leveling the range, grates on the cooktop. The edges of the carefully remove Air Sled and install grates should match up with the edges front leg covers (right and left). of the cooktop.
  • Page 30 NOTE If burner flame looks like 3, the range should not be used until it is serviced. Call 1800-Samsung for service. Normal burner flames shall look like 1 or 2, depending on the gas type you use. 30 English Install_NY9900R_CHEF_NY36R9966PS_AA_DG68-01106B-01_EN+MES+CFR.indb 30...
  • Page 31 Step 14. Final installation checklist To adjust flame low setting You have just completed installing your range. Make sure all controls are in the Identify which burner is exhibiting too high or too low simmer flame size, adjust OFF position and the flow of ventilation air to the range is unobstructed. The as necessary by following steps below: following is a checklist to confirm your range is safely installed and ready for Rotate a knob to "LO"...
  • Page 32 How-to Videos and Live Shows * Requires reader to be installed on your smartphone Please be advised that the Samsung warranty does NOT cover service calls to explain product operation, correct improper installation, or perform normal cleaning or maintenance. QUESTIONS OR COMMENTS?

Table of Contents