Technical specifications
Option modules
Ex protection to ATEX
Mounting location
Permissible ambient temperature for opera-
tion
(For devices with Ex protection: Only in con-
junction with the basic device 6DR5... -.E....
Only T4 is permissible when using I
Alarm module
Binary alarm outputs A1, A2 and alarm output
Signal status High (not responded)
Signal status Low* (responded)
(* Low is also the status when the basic
device is faulty or has not electric power sup-
ply)
Internal capacitance C
i
Internal inductance L
i
Power supply U
H
Connection to power circuits with with the fol-
lowing max. ratings
Binary input BE2
• Electrically connected to the basic device
- Signal status 0
- Signal status 1
- Contact load
• Electrically isolated from the basic device
- Signal status 0
- Signal status 1
- Natural resistance
Static destruction limit
Internal inductance and capacitance
Connection to power circuits with the follow-
ing max. ratings
Electrical isolation
Test voltage
1)
Only in conjunction with the basic device 6DR5...-E..... With Iy module only T4 permitted.
© Siemens AG 2008
Without Ex protection
(EEx d also)
-30 ... +80 °C (-22 ... +176 °F)
module)
y
6DR4004-8A (without Ex protec-
tion)
Active, R = 1 kΩ, +3/-1%*
Disabled, I
< 60 μA
R
(* When used in the flameproof
casing the current consumption
is limited to 10 mA per output.)
≤ 35 V
Floating contact, open
Floating contact, closed
3 V, 5 μA
≤ 4.5 V or open
≥ 13 V
≥ 25 kΩ
± 35 V
The 3 outputs, the input BE2 and the basic device are electrically isolated from each other.
840 V DC, 1 s
Electropneumatic positioners
Technical specifications
With Ex protection Ex ia/ib
II 2G Ex ia/ib II C T4/T5/T6 (only
in conjunction with)
Zone 1
T4: -30 ... +80 °C (-22 ... +176 °F)
T5: -30 ... +65 °C (-22 ... +149 °F)
T6: -30 ... +50 °C (-22 ... +122 °F)
6DR4004-6A (with Ex protection) 6DR4004-6A (with Ex protection)
≥ 2.1 mA
≤ 1.2 mA
(Switching threshold with sup-
ply to EN 60947-5-6: U
= 8.2 V,
H
R
= 1kΩ)
i
5.2 nF
Negligible
intrinsically safe switching
amplifier EN 60947-5-6
=15.5 V DC
U
o
= 25 mA, P = 64 mW
I
k
Floating contact, open
Floating contact, closed
3 V, 5 μA
≤ 4.5 V or open
≥ 13 V
≥ 25 kΩ
Negligible
Intrinsically safe Ui = 25.2 V
840 V DC, 1 s
Siemens FI 01 · 2009
SIPART PS2
Option modules
With Ex n/dust protection
Ex n
II 3 G Ex nA nL[nL] IIC T6
Dust
II 3 D Ex tD A22 IP66 T100°C
Zone 2/22
1)
1)
1)
≥ 2.1 mA
≤ 1.2 mA
(Switching threshold with sup-
ply to EN 60947-5-6: U
= 8.2 V,
H
R
= 1kΩ)
i
5.2 nF (at "nL")
Negligible
at "nA" and "tD":
Un = 15.5 V DC
at "nL":
Ui = 15.5 V DC
Ii = 25 mA
Floating contact, open
Floating contact, closed
3 V, 5 μA
≤ 4.5 V or open
≥ 13 V
≥ 25 kΩ
Negligible
at "nA" and "tD":
Un = 25.2 V DC
at "nL":
Ui = 25.2 V DC
840 V DC, 1 s
6/15