Siemens SIMATIC MOBY D System Manual page 35

Rfid systems
Table of Contents

Advertisement

SLG D11/D11S with ANT D2
Table 4- 7
MDS D124
MDS D160
MDS D324
MDS D424
MDS D460
All values are in mm
SLG D11/D11S with ANT D5
Table 4- 8
MDS D100
MDS D124
MDS D139
MDS D160
MDS D324
MDS D424
MDS D428
MDS D460
MDS D165
MDS D200
MDS D261
All values are in mm
MOBY D
System Manual, 01/2010, J31069-D0147-A6-7618
SLG D11/D11S with ANT D2
Length of the transmission
window (L)
60
50
50
60
50
SLG D11/D11S with ANT D5
Diameter of the
transmission window (L
)
d
∅ 300
∅ 280
∅ 300
∅ 280
∅ 280
∅ 280
∅ 280
∅ 280
∅ 300
∅ 300
∅ 300
Operating distance (S
)
a
45...70
35...55
35...60
45...70
30...50
Operating distance (S
)
a
0...300
0...150
0...280
0...75
0...120
0...150
0...70
0...70
0...220
0...220
0...200
Planning the MOBY D system
4.2 Field data
Limit distance (S
)
g
90
65
70
90
60
Limit distance (S
)
g
380
220
350
110
160
200
100
100
300
320
280
35