C.2 Discontinued SLG with ANT D5
Technical data
Table C- 11
Inductive interface to the MDS
Transmission frequency
Transponders supported
Serial interface to the user
Transmission protocol
Data transmission rate
Data backup
Transmit power
Write/read distances
SLG - MDS
Software functions
Programming
Multitag
Anti-collision speed
Power supply
Current consumption
Cable length, SLG - PC
Antenna cable length
Digital inputs/outputs
Dimensions (L x W x H) in mm
Color
Material
Connectors
SLG fixing
320
Technical data for SLG D11 ANT D5
Rated value
Permitted range
Operation
Inrush current, momentary
With RS 232
For antenna
For the electronics
Antenna
SLG housing
Antenna
SLG housing
Antenna (plugs into SLG)
V24 interface
Power Supply
13.56 MHz
Transponders to ISO 15693 and I-Code1
RS 232
Asynchronous 8 bit
9600 baud to 38.4 Kbaud (adjustable)
CRC 16
1 W
380 mm typically (see field data)
Read, write, initialize MDS, access rights, multitag
Windows 9x, 2000, NT and XP,
with 32 bit DLL available
Yes
approx. 20 labels/s simultaneously identifiable
150 mA
600 mA
30 m
3.60 m
None
340 x 325 x 38
160 x 80 x 40 without connector
Black
Anthracite
Plastic ASA
Plastic PA 12
TNC connector
9-pin Sub-D connector (male)
4-pin M12 connector (male)
2 x M5 screws
System Manual, 01/2010, J31069-D0147-A6-7618