11.2 Error messages and causes for MOBY D with ASM and FC/FB 45 (direct MDS addressing)
Error code in
HEX
06
0A
0B
0C
0D
0F
10
11
12
13
MOBY D
System Manual, 01/2010, J31069-D0147-A6-7618
Flashing of
Cause, remedy
ERR LED
6x
Field interference on SLG
The SLG is receiving interference from its environment.
MDS has left the field during communication.
Communication between SLG and MDS has been interrupted by
external interference.
The distance between two write/read devices is too small and does
not correspond to the configuration guidelines
Antenna error
Antenna is unscrewed
10x
Only during initialization: MDS is unable to perform the initialization
command.
MDS is defective.
11x
Memory of MDS cannot be read correctly.
12x
Memory of the MDS cannot be write-accessed.
Memory of the MDS is defective.
13x
Address error (address range overshoot)
Specified address does not exist on MDS
The command must be checked and corrected when the message
frame is created
The MDS is not the right type.
15x
Start message
This message is output by the ASM after every start. (A start occurs
after connection of the operating voltage, after operating the front
switch, after a rest via the X1 connector or following a bus error.) The
start message remains active until the user issues a RESET command
to the ASM. This enables the user to detect reconnection to the power
supply (and therefore operational readiness) on the ASM.
Execute an init_run
16x
NEXT command is not possible.
SLG does not recognize NEXT command.
17x
Short-circuit or overloading of 24 V outputs
Next command must be a RESET command.
The affected output is turned off.
All 24 V outputs are turned off when total overload occurs.
A reset can only be performed by turning the power supply off and
on again.
Then start init_run.
18x
Internal ASM communication error
Connector contact problem on the ASM (send in ASM for repairs)
ASM hardware defect
Electromagnetic interference
Start init_run command after error correction.
19x
ASM/SLG does not have enough buffer to store the command
intermediately.