Siemens SIMATIC MOBY D System Manual page 272

Rfid systems
Table of Contents

Advertisement

Accessories
10.1 Wide-range power supply unit for SIMATIC RF systems
Table 10- 2
Rated input voltage U
Input voltage range U
Input frequency f
Radio interference level
Switching frequency f
Length of cable
Table 10- 3
Output voltage tolerance ∆U
Overvoltage protection
Noise ∆U
Noise ∆U
Line Regulation
Load Regulation
Short-circuit current I
Settling time t
Temperature coefficient ε
Overload behavior P
Short-circuit protection/
No-load response
Derating
Connector type
Table 10- 4
Input
110 V AC
110 V AC
220 V AC
220 V AC
272
Technical specifications for the input
in
in
in
sw
Technical specifications of the output
out
LF
HF
max
load variations
R
over
Output configurations
Outputs
U1 = U2
24 V DC
24 V DC
24 V DC
24 V DC
EN 60950 / UL 60950
U
= 230 V
in
AC
U
= min., BW: 1 MHz
in
U
= min., BW: 20 MHz
in
U
= min./max.
in
I
= 10...90...10 %
out
I
= 4 A (+50°C)
nom
I
= 10...90...10 %
out
T
= -25 °C to +70 °C
A
T
> +50 °C to +70 °C
A
Flanged connector
Binder,
Order No.: 09-3431-90-04
ILoad =
Efficiency
I1 + I2
(%)
0 A
3 A
≥ 88
0 A
3 A
≥ 90
System Manual, 01/2010, J31069-D0147-A6-7618
100 to 240 V AC
120 to 353 V DC
94 to 264 V AC
120 to 375 V DC
(UL: 353 V
)
DC
50/60 Hz
EN 55011/B
approx. 70 kHz typ.
2 m
U
≤ +2 %/-1 %
out nom
U
+20 % typ.
out nom
≤ 1 % U
out
≤ 2 % U
out
≤ 1,0 %
≤ 1,0 %
105 up to 130 % I
nom
< 5 ms
0.01 %/K
Constant current
Continuous/no-load stability
max. 2 %/K
4 pins
Remarks
No-load stability
No-load stability
MOBY D

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents