Creating a drive object
5.2 Setting the communication interfaces
5.2.3

Assigning the Ethernet interface in STARTER

Assigning the communication interface
1. In STARTER, go through the menu items "Tools > Set PG/PC interface...".
The "Set PG/PC interface" window opens:
Figure 5-2
2. Check the access point of the application. Here, the access point "DEVICE (STARTER,
SCOUT) ..." must be set.
If necessary, correct the access point using the "Access Point of the Application" drop-
down list.
Note
The interface in our example has the designation TCP/IP -> Belkin F5D 5055 Gigabit
USB 2.0 Network Adapter.
However, any Ethernet interface of the PG/PC can essentially be used.