Trane City RTSF050 Installation Operation & Maintenance page 40

Water-cooled liquid chillers with helical rotary compressors
Hide thumbs Also See for City RTSF050:
Table of Contents

Advertisement

Periodic Maintenance
Contractor Confirmation Check
Sheet
This check sheet must be completed by the installing
FWD
contractor and submitted prior to requesting Trane
Power supply
Service start-up support. The check sheet identifies a
Capacities
list of items that need to be completed prior to actual
Cooling capacity on water (1)
machine start-up.
Heating capacity on water (2)
Fan motor
Fan power input (3)
Current amps (3)
Start-up amps
Air flow
Addressed to the Trane Service office of:
minimum
nominal
Job Name:
maximum
Model No.:
Main coil
Water entering/leaving connections
Unit
Electric heater (accessory for blower only)
❏ Unit installed
Electric power supply
Heating capacity
❏ Isolator pads in place
Hot water coil (accessory for blower only)
Heating capacity (4)
Chilled Water
G2 filter (filter box accessory)
Quantity
❏ Connected to the unit
Dimensions ( LxWxth)
G4 filter (filter box accessory)
❏ Connected to the air handling units
Quantity
❏ Connected to the pumps
Dimensions ( LxWxth)
Condensate pump (accessory)
❏ System flushed and then filled
Water flow - lift height
Not available for FWD30 and FWD45
❏ Pumps run and air bled
Sound level (L/M/H speed)
Sound pressure level (5)
❏ Strainers cleaned
Sound power level (5)
Unit dimensions
❏ Flow switch installed and checked/set
Width x Depth
Height
❏ Throttling cock installed in leaving water
Shipped unit dimensions
❏ Thermometers installed in leaving/entering water
Width x Depth
Height
❏ Gauges installed in leaving/entering water
Weight
Colour
Recommended fuse size
Unit alone (aM/gI)
Unit with electric heater (gI)
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
Heat exchanger operating limits:
We will therefore require your service technician on job by*_____________________.
FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars
Checklist completed by____________________________________________________.
Accessories - Hot water coil:
*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars
Date____________________________________________________________________.
* Return this completed checklist to your Trane Service office as soon as possible to enable the start-up visit to
be scheduled. Be aware that advance notification is required to allow scheduling of the start-up as close to the
requested date as possible. Additional time required to complete the start-up and adjustment due to incompleteness
of the installation will be invoiced at prevailing rates.
4
40
Technical Data
08
(V/Ph/Hz)
(kW)
5,2
(kW)
6,3
(type)
(kW)
0,23
(A)
1,1
Contractor Confirmation Check Sheet
(A)
3,2
(m
/h)
490
3
(m
/h)
820
3
Job location:
(m
/h)
980
3
Sales order No.:
(type)
Cooling water
(Dia)
3/4"
❏ Connected to the unit
(V/Ph/Hz)
230/1/50
(kW)
2/4
❏ Connected to the cooling device
(kW)
6,3
❏ Connected to the pumps
2
❏ System flushed and then filled
(mm)
386x221x8
❏ Pumps run and air bled
-
❏ Strainers cleaned
(mm)
-
(type)
❏ Flow switch installed and checked/set
(l/h - mm)
❏ Throttling cock installed in leaving water
(dB(A))
36/40/43
❏ Thermometers installed in leaving/entering water
(dB(A))
46/50/53
❏ Gauges installed in leaving/entering water
(mm)
890 x 600
(mm)
250
❏ Cooling water control operational
❏ Water treatment equipment
(mm)
933 x 644
(mm)
260
Wiring
(kg)
32
❏ Power supply connected and available
(A)
8/16
❏ External interlock connected
(A)
16 (2kW),25 (4kW)
Load
❏ System can be operated under load condition
12
20
230/1/50
8,3
15
11,9
18,9
2 x direct drive centrifugal
0,46
0,65
2,2
3,1
5,5
9,3
980
1400
1650
2300
1970
2600
ISO R7 rotating female
3/4"
1 1/2"
230/1/50 or 400/3/50
400/3/50
8
10
12
17,4
2
2
486x271x8
586x321x8
2
2
486x264x48
586x314x48
Centrifugal
24 - 500
38/41/44
46/50/53
48/51/54
56/60/63
1090 x 710
1290 x 820
300
350
1133 x 754
1333 x 864
310
360
46
61
galvanised steel
8/16
8/16
40 (230V),3*16 (400V)
3*20
30
45
18,8
30,1
20,9
38,2
1,04
1,51
4,7
5,5
14,1
16,5
1800
2700
3000
4500
3600
5400
1 1/2"
1 1/2"
400/3/50
400/3/50
12
12
22,4
34,5
2
2
586*421*8
586*621*8
2
2
586*414*48
586*614*48
47/52/57
47/52/58
57/62/67
57/62/68
1290 x 970
1290 x 1090
450
650
1333 x 1008
1333*1133
460
660
76
118
8/25
8/25
3*25
3*25
UNT-PRC002-GB
RLC-SVX023A