Cooling device bypass – Figure 3
Cooling device bypass is also a valid control method if
the chiller temperature requirements can be maintained.
Advantage:
Sound power levels
• Excellent control by maintaining constant water flow
through the condenser.
Discharge
Disadvantage:
• Higher cost because of the dedicated pump required for
Measurement conditions:
each chiller if condenser pressure is the control signal.
Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
long) fixed to its discharge opening.
Figure 3
Fan
Unit
speed
1
FWD 08
2
1
3
2A
1
FWD 10
2
3
1
7
FWD 12
2
3
1
FWD 14
2
3
1
FWD 20
2
3
Intake
Measurement conditions:
Measurements taken at the horizontal air intake.
Fan
Unit
speed
1
FWD 08
2
3
1
FWD 10
2
3
1
FWD 12
2
3
1
FWD 14
2
3
1
FWD 20
2
3
UNT-PRC002-GB
RLC-SVX023A
3
Power level in dB(A), per Hz frequency band
125
250
55
50
57
54
4
58
57
CO
57
51
58
54
60
58
57
51
CDS
58
54
60
58
56
62
61
66
CI
63
69
5A
57
63
EO
61
66
63
69
6
EVP
EI
Power level in dB(A), per Hz frequency band
125
250
56
55
63
62
66
65
62
58
66
63
70
67
62
58
66
63
70
67
66
65
73
72
78
76
68
72
76
76
78
79
Condenser water pump with variable frequency drive –
Figure 4
Advantages:
• Pumping cost can be reduced. Good cooling device
temperature control.
• Relatively low first cost.
Disadvantage:
• Increased rate of fouling due to lower water velocity in
the condenser.
Figure 4
500
1000
42
37
47
40
50
42
7
45
42
48
45
50
48
45
42
48
45
50
48
50
48
4
55
53
58
56
51
49
55
53
58
56
500
1000
1 = Electric valve actuator
55
53
60
2A = 3-way valve or 2 butterfly valves
60
63
62
2B = 2 butterfly valves
55
58
60
62
3 = RTSF controller
63
65
4 = Refrigerant pressure line
55
58
60
62
5A = Condenser water pump
63
65
65
65
5B = Condenser water pump with VFD
69
71
6 = To/from cooling load
73
75
64
64
7 = To/from cooling device
68
71
71
8 = Electric controller
74
EI = Evaporator Inlet
EO = Evaporator Outlet
CI = Condenser Inlet
CO = Condenser Outlet
Installation - Mechanical
CO
2000
4000
8000
37
31
30
30
38
40
32
40
43
34
33
28
38
39
35
40
42
39
34
33
28
38
39
35
CI
5B
40
42
39
39
38
36
47
46
45
50
50
49
40
39
37
8
47
46
45
50
50
49
EO
EI
2000
4000
8000
46
45
42
53
53
53
56
55
57
51
48
44
56
55
52
59
59
57
51
48
44
56
55
52
59
59
57
57
50
46
64
59
57
69
64
63
56
52
50
65
61
61
69
66
66
Overall power
dB(A)
46
50
53
CDS
48
51
54
48
51
54
56
60
4
63
57
60
63
EVP
Overall power
dB(A)
57
64
67
61
66
69
61
66
69
68
74
78
69
75
78
11
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents