Command And Response Table For Sis Commands - Extron electronics DMS 1600 User Manual

Configurable digital video matrix switchers
Hide thumbs Also See for DMS 1600:
Table of Contents

Advertisement

Command and Response Table for SIS Commands

Symbol definitions for command and response table
]
= CR/LF (carriage return/line feed)
}
= Carriage return (no line feed)
|
= Pipe (can be used interchangeably with the
= Space (hard) character
E
= Escape key (hex 1B)
W
= Can be used interchangeable with the
X!
= Input number (for tie)
X@
= Output
X#
= Mute, front panel lock
X$
= DDC value (EDID) (see the
X%
= Input number
X^
= Global preset number
X&
= Room number (for room presets)
NOTE: A room is a subset of operator selected outputs that relate to each other. The DMS matrix switcher
supports up to 10 rooms, each of which can consist of from 1 to 16 outputs.
X*
= Name
NOTE: The following characters are invalid or not recommended in the name: ~ , @ = ' [ ] { } < > " : | \ and ?.
X(
= Room preset number
NOTE: A room preset is a stored configuration with all of the outputs assigned to a single room. When a room
preset is recalled from memory, it becomes the current configuration.
X1)
= Connection status
X1!
= Group number (for I/O grouping)
X1@
= Number (quantity) of inputs
X1#
= Number (quantity) of outputs
X1$
= Board installed
X1%
= Part number
X1^
= Firmware version number to second decimal place (x.xx)
X1&
= Verbose firmware version-description-
upload date/time
X1*
= Voltage
X1(
= Temperature
X2)
= Fan speed
X2!
= Power supply status
}
character)
E
character
00 – 16 , 20 , 32 , or 36 (the highest numbered input for your model) ( 00 = untied)
01 – 16 , 20 , 32 , or 36 (the highest numbered output for your model)
0 = not muted/not locked, 1 = muted/locked
EDID Table
on page 52)
01 – 16 , 20 , 32 , or 36 (the highest numbered input for your model)
00 through 32 ( 00 = current configuration)
01 through 10 (each can have up to 10 room presets [
Up to 12 characters for input and output names, global preset names, and room
preset names
11 characters maximum for room names
Upper-and lower-case alphanumeric characters are valid
01 through 10
0 = no input connected
1 through 4 (or 0 = no group)
4 , 8 , 12 , 16 , 20 , 24 , 28 , 32 , 36
4 , 8 , 12 , 16 , 20 , 24 , 28 , 32 , 36
X0 = No board installed
C1 = DVI 4 inputs x 4 outputs
C2 = DVI 4 inputs x 0 outputs
C3 = DVI 0 inputs x 4 outputs
60 -nnnn- 01
See the
Positive or negative voltage and magnitude
Degrees Fahrenheit
In revolutions per minute (RPM)
0 = not installed or failed
DMS 1600, DMS 2000, DMS 3200, and DMS 3600 • Programming Guide
1 = input connected
D1 = Fiber 4 inputs x 4 outputs
D2 = Fiber 4 inputs x 0 outputs
D3 = Fiber 0 inputs x 4 outputs
Query controller firmware version (verbose)
1 = installed and OK
X(
s] assigned)
command on page 57
50

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dms 2000Dms 3200Dms 3600