(6) P parameters
Display
Function name
code
P055 Pulse-string frequency scale
Time constant of pulse-string frequency
P056
filter
P057 Pulse-string frequency bias
P058 Pulse-string frequency limit
P060 Multistage position setting 0
P061 Multistage position setting 1
P062 Multistage position setting 2
P063 Multistage position setting 3
P064 Multistage position setting 4
P065 Multistage position setting 5
P066 Multistage position setting 6
P067 Multistage position setting 7
P068 Zero-return mode selection
P069 Zero-return direction selection
P070 Low-speed zero-return frequency
P071 High-speed zero-return frequency
P072 Position range specification (forward)
P073 Position range specification (reverse)
P074 Teaching selection
P100 Easy sequence user parameter U (00)
P101 Easy sequence user parameter U (01)
P102 Easy sequence user parameter U (02)
P103 Easy sequence user parameter U (03)
P104 Easy sequence user parameter U (04)
P105 Easy sequence user parameter U (05)
P106 Easy sequence user parameter U (06)
P107 Easy sequence user parameter U (07)
P108 Easy sequence user parameter U (08)
P109 Easy sequence user parameter U (09)
P110 Easy sequence user parameter U (10)
P111 Easy sequence user parameter U (11)
P112 Easy sequence user parameter U (12)
P113 Easy sequence user parameter U (13)
P114 Easy sequence user parameter U (14)
P115 Easy sequence user parameter U (15)
P116 Easy sequence user parameter U (16)
P117 Easy sequence user parameter U (17)
P118 Easy sequence user parameter U (18)
P119 Easy sequence user parameter U (19)
P120 Easy sequence user parameter U (20)
P121 Easy sequence user parameter U (21)
P122 Easy sequence user parameter U (22)
P123 Easy sequence user parameter U (23)
P124 Easy sequence user parameter U (24)
P125 Easy sequence user parameter U (25)
P126 Easy sequence user parameter U (26)
P127 Easy sequence user parameter U (27)
P128 Easy sequence user parameter U (28)
P129 Easy sequence user parameter U (29)
P130 Easy sequence user parameter U (30)
P131 Easy sequence user parameter U (31)
Range of setting
10 to 500
1 to 200
-100 to +100
0 to 100
Position setting range reverse side to forward
side
Position setting range reverse side to forward
side
Position setting range reverse side to forward
side
Position setting range reverse side to forward
side
Position setting range reverse side to forward
side
Position setting range reverse side to forward
side
Position setting range reverse side to forward
side
Position setting range reverse side to forward
side
0(Low) / 1 (Hi1) / 0 (Hi2)
0 (FW) / 1 (RV)
0 to 1000
0 to 40000
0 to 268435455 (when P012 = 02)
0 to 1073741823 (when P012 = 03)
-268435455 to 0 (when P012 = 02)
-1073741823 to 0 (when P012 = 03)
0 (X00) / 1 (X01) / 2 (X02) / 3 (X03) /4 (X04) /
5 (X05) / 6 (X06) / 7 (X07) /
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
8 - 17
Chapter 8 Appendix
Minimum
Setting during
Updating during
operation
operation
unit
(allowed or not)
(allowed or not)
×
0.1 (kHz)
×
0.01 (s)
×
1 (%)
×
1 (%)
1(pulse)
1(pulse)
1(pulse)
1(pulse)
1(pulse)
1(pulse)
1(pulse)
1(pulse)
0.01Hz
0.01(Hz)
1(pulse)
1(pulse)