MZ-N10
Charging Information Clear of Built-in Lithium-ion
Rechargeable Battery
Function of recording the charging information is equipped for
design confirmation.
There are two informations only for buit-in lithium-ion recharge-
able battery.
• Remaining charging time
• The number of times of fully charging
Initialization of the information is required at replacement of built-
in rechargeable battery since it is pequliar to the buit-in lithium-
ion rechargeable battery.
Perform the initialization as the following procedure.
1. Select the manual mode of the test mode, and set item number
043 (Resume clear and time set clear).
Remote commander LCD display
043
Resume 00
[VOL +]
2. Adjust with the
comes 02, and press the X key or
commander.
Remote commander LCD display
043
****
3. Resume clear is completed when the following display appears.
Remote commander LCD display
043
ResClr
4. Press the x key to return to the test mode (display check
mode).
36
adjusted value
key so that the adjusted value be-
key on the remote
02