Electrical Adjustments - Sony MZ-N10 Notes: installing & operating OpenMG Service Manual

Minidisc & dat walkman: high speed net md walkman recorder
Hide thumbs Also See for MZ-N10 Notes: installing & operating OpenMG:
Table of Contents

Advertisement

Outline
• In this set, automatic adjustment of CD and MO can be per-
formed by entering the test mode.
However, before starting automatic adjustment, the memory
clear, power supply adjustment, and laser power check must be
performed in the manual mode.
• A key having no particular description in the text, indicates a
set key.
• For the LCD display, the LCD on the remote commander is
shown, but the contents of LCD display on the set are same.
Precautions for Adjustment
1. Adjustment must be done in the test mode only.
After adjusting, release the test mode.
2. Use the following tools and measuring instruments.
• Test CD disc
TDYS-1
• SONY MO disc available on the market
• Digital voltmeter
• Laser power meter
LPM-8001
(Part No. : J-2501-046-A)
• AC adaptor (6V) and USB cradle
• Personal computer
• USB cable
• Regulated dc power supply (two sets)
• Thermometer (using the Temperature Correction)
3. Unless specified otherwise, use AC adaptor (6V) and USB
cradle.
4. Switch position
HOLD switch ............................................... ON
Adjustment Sequence
1. NV Reset (item number: 021)
(EEPROM clear)
r
2. Temperature Correction (item number: 015)
r
3. Power Supply Manual Adjustment
r
4. Laser Power Check and Adjustment
r
5. Adjustment required before Overall
Adjustment
r
6. CD Overall Adjustment (item number: 031)
r
7. MO Overall Adjustment (item number: 034)
r
8. RESUME Clear (item number 043)
r
9. Rewriting the Patch Data
(at replacement of the MAIN board)
r
10. Rewriting the NV values
Note: "2. Temperature Correction" and "3. Power Supply Manual Adjust-
ment" can be performed continuously with pressing the
[P MODE]
key or the
key on the remote commander in the overall
adjustment mode.
SECTION 5

ELECTRICAL ADJUSTMENTS

(Part No. : 4-963-646-01)
Manual Mode
Manual Mode
Manual Mode
Manual Mode
Overall Mode
Manual Mode
[VOL --]
NV Reset
Caution: The shipment data will be cleared without the adjusted
values of the electrical offset adjustment and power sup-
ply adjustment when the NV is reset.
• Setting method of NV reset
1. Select the manual mode of the test mode, and set item number
021 NV Reset (see page 12).
Remote commander LCD display
021
ResNV CC
2. Press the
X
key.
Remote commander LCD display
021
ResOK?
3. Press the
key once more.
X
Remote commander LCD display
021
Res***
NV reset (after several seconds)
021
Reset!
4. Press the
key to quit the manual mode, and return to the
x
test mode (display check mode).
Temperature Correction
• Adjustment method of temperature correction
1. Select the manual mode of test mode, and set the item number
015 (see page 12).
Remote commander LCD display
015
SetTmp
** : Adjusted value
2. Measure the ambient temperature.
[VOL +]
[VOL --]
3. Adjust with
,
(hexadecimal value) becomes the ambient temperature.
(Initial value: 19h = 25 °C, Adjusting range: 80h to 7fh (–128
°C to +127 °C)
4. Press the
key to write the adjusted value.
X
5. Press the
key to quit the manual mode, and return to the
x
test mode (display check mode).
Note : Power supply adjustment auto item feed mode (see page
22 ) is available to perform the temperature correction and
power supply adjustment without entering the manual mode.
MZ-N10
@
**
key so that the adjusted value
17

Advertisement

Table of Contents
loading

Table of Contents