Test Mode - Sony MZ-N10 Notes: installing & operating OpenMG Service Manual

Minidisc & dat walkman: high speed net md walkman recorder
Hide thumbs Also See for MZ-N10 Notes: installing & operating OpenMG:
Table of Contents

Advertisement

Outline
• This set provides the Overall adjustment mode that allows CD
and MO discs to be automatically adjusted when in the test mode.
In this overall adjustment mode, the disc is discriminate between
CD and MO, and each adjustment is automatically executed in
order. If a fault is found, the system displays its location. Also,
the manual mode allows each individual adjustment to be auto-
matically adjusted.
• Operation in the test mode is performed with the set. A key
having no particular description in the text, indicates a set key.
• For the LCD display, the LCD on the remote commander is
shown, but the contents of LCD display on the set are same.
(Both displays may be displayed.)
Setting Method of Test Mode
There are three different methods to set the test mode:
1 Short SL803 (TEST) on the MAIN board with a solder bridge
(connect pin <zx. of IC801 to the ground) and turn on the power.
– MAIN Board (Side B) –
IC801
2 In case of setting the test mode only by keys on the set:
In the normal mode, turn on the [HOLD] switch. While press-
ing the [GROUP] key press the following order:
t
t
t
>
>
.
t
t
t
.
>
.
SECTION 4

TEST MODE

TP1829
1-686-347-
SL803 (TEST)
t
t
.
>
t
X
X
3 In case of setting the test mode by keys on the set and
remote commander:
In the normal mode, turn on the
While pressing the
key on the set, press the keys on the
x
remote commander with the following order:
t
t
>
>
.
t
t
.
>
.
Note: If electrical adjustment (CD and MO overall adjustment) has not
been finished completely, "ERROR" is displayed on LCDs of the
set and the remote commander.
Operation in Setting the Test Mode
• When the test mode becomes active, first the display check mode
is selected.
• Other mode can be selected from the display check mode.
• When the test mode is set, the LCD repeats the following dis-
play.
Remote commander LCD display
All lit
All off
Microcomputer
version
V1.100
display
Set LCD display
All lit
All off
001
Microcomputer
version
Ver 1.100
display
• When the
key is pressed and hold down, the display at that
X
time is held so that display can be checked.
Releasing the Test Mode
For test mode set with the method 1:
Turn off the power and open the solder bridge on SL803 (TEST)
on the MAIN board.
Note: Remove the solders completely. Remaining could be shorted with
the chassis, etc.
For test mode set with the method 2 or 3:
Turn off the power.
MZ-N10
[HOLD]
switch on the set.
t
t
t
.
>
t
t
11