Graco PR70 Repair And Parts Manual page 17

Two component liquid dispensing systems
Hide thumbs Also See for PR70:
Table of Contents

Advertisement

Problem
Material dispensed not correct weight Specific gravity of one or more of the
Machine dispensing off ratio
Pumps drawing material back from
valve hose
312760Y
Cause
two materials has changed since cali-
bration
Machine air pressure has changed
since calibration.
Not enough material in one or more
tanks
Mixer has slight obstruction
Check valve malfunction
Piston worn or broken
One tank is empty
Tank ball valve closed
Machine out of phase
Check valve malfunction
Piston worn or broken
Check valve stuck open
Troubleshooting
Solution
Recalibrate machine.
Readjust air pressure regulator to
value used when machine was cali-
brated, or recalibrate machine.
Check tank levels; fill and prime as
necessary.
Replace static mixer. Prime machine.
Remove check valve; clean or
replace as necessary.
Replace piston.
Check tank levels. Add material if
necessary.
Open tank ball valve. Prime machine.
Rephase machine.
Remove check valve; clean or
replace as necessary.
Replace piston.
Remove check valve, clean or
replace as necessary.
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pr70v

Table of Contents