Teledyne 4700 Pocket Manual page 100

Refrigerated sampler
Hide thumbs Also See for 4700:
Table of Contents

Advertisement

4700 Refrigerated Sampler
2.
The sampler displays the Time or Flow
pacing option screen. Use the Next or
Previous button to select TIME PACED.
Then press the Enter button.
3.
The sampler displays the pacing interval
screen. Use the Number buttons to type
the pacing interval in hours and minutes
(0 hours, 15 minutes). Press the Enter
button.
4.
The sampler displays the option to enter
a sample volume or use the defined
volume. Select ENTER SAMPLE
VOLUME and press Enter.
5.
The sampler displays the Volume
Dependent On Flow screen. Select YES
and press Enter.
6.
The sampler displays a screen to select
the flow rate input. Our sampler is
connected to a 4-20 mA input signal.
Therefore, select ANALOG INPUT and
press Enter.
3-52
TIME PACED
FLOW PACED
SAMPLE EVERY
___ HOURS, ___ MINUTES
ENTER SAMPLE VOLUME
USE DEFINED SAMPLE
VOLUMES DEPENDENT
ON FLOW?
FLOW PULSES
ANALOG INPUT
YES
NO

Hide quick links: