Note
Precondition for changing the OD indexes of the SINAMICS mapping parameters
To allow you to change the values of the mapping parameters, you must set the COB ID
of the corresponding parameter to invalid. To do this, add a value of 80000000 hex to the
COB-ID. You must reset the COB-ID to a valid value once you changed the mapping
parameters.
OV index:
You have now configured and mapped the process data.
Free RPDO mapping - Overview
Fieldbuses
Function Manual, 04/2018, FW V4.7 SP10, A5E34229197B AE
Free objects (Page 203)
Objects of the drive profile CiA 402 (Page 204)
Communication over CANopen
6.3 PDO services