Siemens SINAMICS G110M Function Manual page 159

Fieldbus systems
Hide thumbs Also See for SINAMICS G110M:
Table of Contents

Advertisement

Instance
Object name
ID
AV17
FREQ SP PCT
AV18
ACT FAULT
AV19
PREV FAULT 1
AV20
PREV FAULT 2
AV21
PREV FAULT 3
AV22
PREV FAULT 4
AV25
SEL STPT
AV28
AO1 ACT
AV29
AO2 ACT
AV30
MIN Speed
AV31
MAX Speed
AV32
ACCEL TIME
AV33
DECEL TIME
AV34
CUR LIM
AV39
ACT WARN
AV40
PREV WARN 1
AV41
PREV WARN 2
AV5000 RAMP UP TIME
AV5001 RAMP DOWN TIME
AV5002
FILTER TIME
AV5003 DIFF TIME
AV5004 PROP GAIN
AV5005 INTEG TIME
AV5006 OUTPUT MAX
AV5007 OUTPUT MIN
AV5100 RAMP UP TIME 0
AV5101 RAMP DOWN TIME 0
AV5102 FILTER TIME 0
Fieldbuses
Function Manual, 04/2018, FW V4.7 SP10, A5E34229197B AE
5.5 Communication via BACnet MS/TP - only CU230P-2 HVAC / BT
Description
Setpoint 1 (when controlling via
BACnet)
Number of the fault due to be
dealt with
Number of the last fault
Number of the fault before last
Number of the fault third from
last
Number of the fault fourth from
last
Command to select the setpoint
source
Signal from AO 1
Signal from AO 1
Minimum speed
Maximum speed
Ramp-up time
Ramp-down time
Current limit
Indication of a pending alarm
Indication of the last alarm
Indication of the last but one
alarm
Technology controller ramp-up
time
Technology controller ramp-
down time
Technology controller actual
value filter time constant
Technology controller differenti-
ation time constant
Technology controller propor-
tional gain
Technology controller integral
time
Technology controller maximum
limiting
Technology controller minimum
limiting
Technology controller 0 ramp-up
time
Technology controller 0 ramp-
down time
Technology controller 0 actual
value filter time constant
Communication via RS485
Unit
Range
%
-199.99 ... 199.99
---
inverter-dependent
---
inverter-dependent
---
inverter-dependent
---
inverter-dependent
---
inverter-dependent
---
0 ... 32767
mA
inverter-dependent
mA
inverter-dependent
RPM
0.000 – 19500,000
RPM
0.000 ... 210000.00
0
s
0.00 ... 999999.0
s
0.00 ... 999999.0
A
inverter-dependent
---
inverter-dependent
---
inverter-dependent
---
inverter-dependent
s
0 ... 650
s
0 ... 650
s
0 ... 60
s
0 ... 60
s
0 ... 1000
s
0 ... 1000
%
- 200 ... 200
%
- 200 ... 200
s
0 ... 650
s
0 ... 650
s
0 ... 60
Access
Parameter
type
C
HSW
R
r0947[0]
R
r0947[1]
R
r0947[2]
R
r0947[3]
R
r0947[4]
W
p1000
R
r0774.0
R
r0774.1
W
p1080
W
p1082
W
p1120
W
p1121
R
p0640
R
r2110[0]
R
r2110[1]
R
r2110[2]
W
p2257
W
p2258
W
p2265
W
p2274
W
p2280
W
p2285
W
p2291
W
p2292
W
p11057
W
p11058
W
p11065
157